beautypg.com

Atec Aeroflex-IFR-3416 User Manual

Page 10

background image

on the LVDS connector. These can be used to synchronize to an exter-
nally applied clock.

INTERNAL IQ DATA OUT

16-bit IQ data is available on the LVDS interface when the modulation
is generated internally. Outputs can be disabled.

TONES

A tone (CW) only mode is available. Up to 2 tones may be selected.
Each tone may be independently enabled and disabled.

Frequency Range

carrier frequency ± 10 MHz

Relative Level

60 dB

When differential I/Q outputs are enabled signal generator RF carrier
output is CW only.

Output Impedance

Can be used with single ended 50

loads or differential 100

loads.

Delivered bias voltages are halved with single ended loads.

I/Q Bias Voltages

Independent I and Q channel bias voltages settable within the range of
± 3 V

Bias Voltage

Resolution

1.0 mV nominal

Accuracy

± 2% ± 4 mV max, ± 1% ± 2 mV typical

Offset

See Bias Voltage above.

Differential Offset Voltage

Range

± 300 mV

Resolution

100 µV nominal

Accuracy

± 2% ± 3.3 mV max, ± 1% ± 0.7 mV typical

Level Mode

Variable IQ signal level over 45 dB range

Differential Signal Balance

typ 0.15 dB @10 MHz

I/Q Channel Balance

± 0.2 dB @1 MHz

I/Q Level Imbalance Adjust

± 4 dB nominal continuously variable

I/Q Signal Amplitude

22.4 mV to 4 V pk-pk per channel

I/Q Signal Amplitude Accuracy

< 2% at 20 kHz, typ 1.5%, excludes termination errors

Baseband Purity (2 V p-p set voltage at 1 MHz)

2nd Harm -70 dBc
3rd Harm -65 dBc
IMD -70 dBc (100 kHz tone spacing, at 1 MHz)

Provides a digital sweep of RF frequency, RF level and Analog
Modulation Sources in discrete steps

Start, stop, step size, number and step time can be controlled. Step
time may be set from 2.5 ms to 10 s with 0.1 ms resolution. (20 ms
for mechanical attenuator Option 002)

The sweep can be set to be continuous, single or externally triggered
from the rear panel. TTL BNC Female rear panel.

Frequency Sweep

Linear step size: 1 Hz minimum step

Logarithmic: 0.01% to 50%, 0.01% step

Level Sweep

0.01 dB minimum step

Modulation Oscillator

0.1 Hz minimum frequency step

LIST MODE

Up to 500 frequencies and levels can be entered in the list. Start
address, stop address and dwell time can be controlled. Dwell time
can be set from 500 µs to 10 s. Requires Option 003 Electronic
Attenuator

This option requires Electronic Attenuator Option 003 to be fitted.

On/Off Ratio

> 80 dB for carrier levels -60 dBm

Rise/Fall Time

< 20 ns typical (10 to 90%)

Pulse Delay

Typically < 50 ns

RF Level Accuracy

The above specification is met for all power levels above 150 MHz.

AM Depth and Distortion

AM operation is unspecified below 10 MHz.
AM depth and distortion specification is degraded for operation above
0 dBm at carrier frequencies < 150 MHz.

Video Breakthrough

RF Mode

Power

< ± 50 mV for RF levels > + 10 dBm
< ± 25 mV for RF levels in the range -10 dBm to + 10 dBm
< ± 10 mV for RF levels -10 dBm

Noise

< ± 50 mV for RF levels > + 4 dBm
< ± 25 mV for RF levels in the range -16 dBm to + 4 dBm
< ± 10 mV for RF levels -16 dBm

ACP

< ± 50 mV for RF levels > -6 dBm
< ± 25 mV for RF levels in the range -26 dBm to -6 dBm
< ± 10 mV for RF levels -26 dBm

Modulation Source

PULSE IN BNC (female) connector rear panel

Input Impedance

50

Input Level

TTL level (HCT)

Control Voltage

A HCT logic 0 (0 V to 0.8 V) turns the carrier OFF
A HCT logic 1 (2 V to 5 V) turns the carrier ON

Max. Safe Input Level

± 10 V

Full instrument configurations can be saved to 100 memory stores
(0 - 99).