Calibration cycle
1 year
Environmental
Agilent Technologies outdoor
equipment class
1
MIL–PRF–28800F class 2
Altitude – operating
9,144 m (30,000 ft)
Under battery operation
[AC to DC adapter rated at 3,000 m (9,840 ft)]
Altitude – non–operating
15,240 m (50,000 ft)
Intrusion protection
IP 30 IEC/EN 60529
Temperature range
Operating
AC power
–10 to 55 °C
Battery
–10 to 50 °C
-10 to 55 °C (typical)
Storage
–51 to 71 °C
With the battery pack removed.
The battery packs should be stored in an
environment with low humidity. Extended
exposure to temperature above 45 ºC could
degrade battery performance and life.
EMC
Complies with European
EMC
Directive 2004/108/EC
EC/EN 61326–1
CISPR Pub 11 Group 1, class A
AS/NZS CISPR 11
ICES/NMB–001
ESD
IEC/EN 61000–4–2
Safety
Complies with European
Low Voltage Directive
2006/95/EC
EC/EN 61010–1 2
nd
Edition
Canada: CSA C22.2
No. 61010–1–04
USA: UL 61010–1 2
nd
Edition
Power
Power supply
External DC input
15 to 19 VDC
40 W maximum when battery charging
External AC power adapter
Efficiency Level IV, 115 VAC
Input
100 to 250 VAC, 50 to 60 Hz
1.25 – 0.56 A
Output
15 VDC, 4 A
Power consumption
On: 14 W (typical)
1. Samples of this product have been type tested in accordance with the Agilent Environmental Test Manual (ETM) for outdoor
equipment (OE) and verified to be robust against the environmental stresses of storage, transportation and end use; those
stresses include but are not limited to temperature, humidity, shock, vibration, altitude and power line conditions