beautypg.com

System specifi cations, Software – Atec Agilent-34972A User Manual

Page 19

background image

19

System specifi cations

Scanning inputs
Analog 34901A,

34902A,

and

34908A

multiplexer

channels

Digital

34907A digital in and totalize

Scan list

Scans channels in ascending order

Scan triggering
Source

Interval, external, button press, software,

or on monitor channel alarm

Scan count

1 to 50,000 or continuous

Scan interval

0 to 99 hours; 1 ms step size

Channel delay

0 to 60 seconds per channel; 1 ms step size

External trig delay

<300 µs. With monitor on <200 ms

External trig jitter

<2 ms

Alarms
Analog inputs

Hi, Lo, or Hi + Lo evaluated each scan

Digital inputs

34907A digital in maskable pattern match

or state change

34907A totalize: Hi limit only

Monitor channel

Alarm evaluated each reading

Alarm outputs

4 TTL compatible

Selectable TTL logic Hi or Lo on fail

Latency

5 ms (typical)

Memory
Battery

34970A, 4-year typical life

[1]

,

34972A User replaceable battery.

Recommend replacement once a year

during

CAL.

Readings

50,000 internal readings with timestp

Readable during scan

States

5 instrument states with user label

Alarm queue

Up to 20 events with channel number,

reading, and timestamp

USB flash drive

Support FAT or FAT 32 format

System features
Per-channel math

Individual Mx + B scaling and

Min/Max/Average calculated real time

Power fail recovery

Resumes scanning automatically

Relay maintenance

Counts each relay closure and stores

on module User resettable

Real-time clock

Battery-backed, 4-year typical life

[1]

General specifications
Power supply

100 V/120 V/220 V/240 V ± 10%

Power line frequency

45 Hz to 66 Hz automatically sensed

Power consumption

12 W (25 VA peak)

Operating environment

Full accuracy for 0 °C to 55 °C

Full accuracy to 80% R.H. at 40 °C

Storage environment

-40 °C to 70 °C

[1]

Weight

Net: 3.6 kg (8.0 lbs)

Safety

Conforms to CSA, UL-1244, IEC 1010 Cat I

RFI and ESD

CISPR 11, IEC 801/2/3/4

Software

Agilent 34825A BenchLink Data Logger 3
(included with option DMM)

System requirements

[2]

Operating system

Windows Vista

®

, XP SP2, 2000 SP4 (does

not support any home editions),

Adobe

®

Acrobat

®

Reader V5.0 or higher

(to view documentation)

Microsoft Internet Explorer V6.0 or higher

(required when using Windows NT)

Controller Recommend

Pentium

®

4, 800 MHz or

greater, Min: Pentium III, 500 MHz

RAM

Recommend 256 MB or greater,

Min 128 MB

Disk space

Recommend 200 MB, Min 100 MB

Display

Recommend 1024 x 768 resolution,

256

colors

Computer interfaces

[3]

34970A
GPIB

Agilent and National Instruments PCI-GPIB

RS-232 (Serial port)

PC COM 1-4

34972A
LAN

10/100/1000 BaseT

USB

USB 2.0

Agilent BenchLink features
Configuration

Spreadsheet-like channel configurations

page.

Upload and Download instrument

configurations.

Computed channels using ± */, dB, dBm,

dBV,

x

2

, √

x and full, ½, or ¼ bridge strain

Graphical displays

Real-time and historical data displays

Add, delete, size, and configure real time

Strip chart with markers and alarm indication,

bar and scatter charts, Histogram with

statistics, Bar meter, and Data table

Graphical controls

Sliders, switches, buttons, and LED lights

Alarm/limit testing

Start/Stop scanning on alarm condition

Control 34903A relay state or 34907A

digital output on alarm

Data

Real time streamed (saved) to disk

Automatically export data and

configurations

Copy data or graphics to windows clipboard

Export your selected data to .CVS, .XML,

or .TXT formats

Event logging

Automatic entry of alarms and errors

Instrument driver support for programming languages
IVI-C or IVI-COM driver

Compatible with Windows

®

7, Vista SP1,

XP SP2 (32-bit) IO Libraries 14.1 or greater.

Supports Agilent VEE, Visual Basic, C/C#,

Visual Studio, National Instruments

LabWindows CVI and LabVIEW

LabVIEW driver (VI)

LabVIEW 7.0 or greater

Controller

Recommend 800 MHz or greater,

minimum 600 MHz.

[1]

Storage at temperatures above 40 °C will decrease battery life

[2]

Software provided on CD-ROM

[3]

Interface and driver must be purchased and installed separately

[4]

Requires VISA command library for IEEE-488