beautypg.com

Associated Equipment 12-1015 Manual User Manual

Page 43

background image

-

43 -

Model 12-1015 Users’ Manual Version 13.08

Associated Equipment Corp.

5043 Farlin Ave.

800-949-1472(US)

St. Louis, MO 63115

314-385-5178 (Outside US)

No Load Test

At 3,000 rpm:

Av Volts: 14.2V

<15.0V: Max. 14.6V

>13.3V: Min. 13.8V

Press [Enter] for

results.

Start the engine and then press key again and the screen will

prompt you as shown below (Fig. 59).














Follow the instructions, make sure that all loads (lights, air-condition, etc)

are OFF. Rev the engine up to 3,000 ~ 3,500 RPM by referring to the

dashboard meter, then press key and maintain the engine speed for

about 10 seconds and release the pedal. The maximum and minimum

voltages values will be captured.


After that press key again and it show as below (Fig 60.)
















With the captured readings, analysis can done by referring to the limits as
indicated that MAX voltage should not exceed 15.0V (max. voltage at
3,000 RPM) and MIN voltage should be more than 13.3V (min voltage
during idling speed).

Figure 60

Figure 59

Average
Charging Volts

Charging Volts
range limit.

Captured Volts
readings

No Load Test

Make sure all

electrical loads are

turn OFF. Rev the

engine to 3,000 rpm.

Press [Enter].Hold

on to this 3,000 rpm

for 10 seconds and

release the pedal.