beautypg.com

Associated Equipment 12-1015 Manual User Manual

Page 16

background image

-

16 -

Model 12-1015 Users’ Manual Version 13.08

Associated Equipment Corp.

5043 Farlin Ave.

800-949-1472(US)

St. Louis, MO 63115

314-385-5178 (Outside US)












Here, it will let you select your choice from the Menu:

New: Clear Memory

Selecting this item will allow the tester to clear the last tested results
stored in its memory and begin a new test.

Continue Testing
Selecting this item will allow you to continue the last test on the same car
from where you had stopped.

For example:
If you had done Battery Test and later, you wish to do Alternator Test or
Grounding Test on the same car, just select this item and it will update
the results after each test in its memory so that it can be review later or to
be printed out.

View Last Test

Here it will let you review all the test results of the last tested car. The
results stored will always be the updated ones which depend on the tests
that had been done.

Use or keys to scroll for the pages during viewing.

Examples:











Figure 17

Figure 15

Figure 16

Select Menu

New: Clear Memory

Continue Testing

View last Test

Setup Menu

Then press [Enter].

Battery: Good

Measured: 406 CCA

Rating: 630 CCA

Volts: 12.45 V

Int. R: 6.72 mOhm

Life: 76 %

Results: High Ohms

The grounding

resistance of the

engine or car

chassis is high.

Clean the cable

contacts or

replace cable if

necessary.