beautypg.com

Achange & gasket installation, Side knockout removal, panel, P/b 1 4 – Alpha Technologies Te45 User Manual

Page 60: Detail a - inside view, Rear view, Right side view power enclosure shown, Insulation cut detail detail b - inside view

background image

NAME

DATE

APPROVED

CHECKED

DRAWN

DESIGN

2009/09

2009/09

2009/09

2009/09

ME

KL

ME

JK

SCALE:

THESE DESIGNS AND SPECIFICATIONS ARE CONFIDENTIAL, REMAIN

THE PROPERTY OF ARGUS TECHNOLOGIES LTD., AND SHALL NOT

BE COPIED OR USED WITHOUT ITS WRITTEN CONSENT.

TYPE

0.5

D2

1

0.5

0.05

0.002]

[ 0.040]

[ 0.020]

[

UNITS: mm [in]

X [X.X]

X.X [X.XX]

X.XX [X.XXX]

ANGULAR:

OF

20

10 ALPHA TECHNOLOGIES

TITLE:

ISSUE

DATE
SIZE

B

DWG NO.

CUSTOMER CONNECTION,

KIT, INTERFACE, w/ CBL

SET, PWR TO BATT, Te45

747-670-08

SHEET

NTS

REV

P/B

1

4

ITEM

QTY

ME

2009/12

SDW

JK

UPDATED WIRING

P/B

REVISIONS

DESCRIPTION

LTR

APPD

DATE

DWN

CHKD

POWER AND BATTERY ENCLOSURE CONFIGURATION

SETUP & PREPARATION:

DETAIL A - INSIDE VIEW

B

REAR VIEW

Te45 POWER ENCLOSURE

Te45 BATTERY ENCLOSURE

A

CHANGE & GASKET INSTALLATION:

RIGHT SIDE VIEW

POWER ENCLOSURE SHOWN

IN ENCLOSURE MANUALS.

FOLLOW INSTALLATION PROCEDURE PROVIDED

BEFORE INSTALLING ENCLOSURE TO PAD.

REMOVE TOP CORNER KNOCKOUTS ON FACING

SIDES OF BOTH ENCLOSURES (2 PER SIDE)

TO ACCEPT BOLTING HARDWARE

REMOVE SIDE ACCESS CABLE

KNOCKOUTS ON FACING SIDES

OF BOTH ENCLOSURES.

INSTALL SEALING GASKET (ITEM 6)

AROUND K.O. OPENINGS ON

POWER ENCLOSURE SIDE ONLY.

SIDE KNOCKOUT REMOVAL, PANEL

6
2

EXISTING

CUT LINES

CUT AWAY A SMALL SECTION OF INNER

WALL INSULATION IN AREA OF SIDE

ACCESS CABLE KNOCKOUTS ON

BOTH ENCLOSURES AS SHOWN FOR

CHASE NIPPLE INSTALLATION.

INSULATION CUT DETAIL

DETAIL B - INSIDE VIEW

©