background image

325

path according to the current path. If you omit this parameter,

it will redirect to an empty page.

Example: Drive the digital output 1 to triggered state and redirect to an empty page

http://myserver/cgi-bin/dido/setdo.cgi?do1=1



Query status of the digital input

Note: This request requires the privilege of viewer.

Method: GET/POST


Syntax:

http://<servername>/cgi-bin/dido/getdi.cgi?[di0][&di1][&di2][&di3]

If no parameter is specified, all the status of digital input will be returned.


Return:

HTTP/1.0 200 OK\r\n Content-

Type: text/plain\r\n Content-Length:

\r\n

\r\n [di0=]\r\n

[di1=]\r\n

[di2=]\r\n

[di3=]\r\n

where can be 0 or 1.


Example: Query the status of digital input 1

Request:

http://myserver/cgi-bin/dido/getdi.cgi?di1

Response:

HTTP/1.0 200 OK\r\n Content-

Type: text/plain\r\n Content-

Length: 7\r\n

\r\n

di1=1\r\n