beautypg.com

ABUS AZ6301 Terxon PSTN dialer User Manual

Page 55

background image

55

1. Enter your programming code (default: 1234). The following

message is shown in the display:

READY


Press

. The display shows the following:

ROUTE-


Press

to display the current allocation of telephone numbers to

alarm message A. In this example, the alarm message A is transferred
to telephone numbers 1 and 3.

A> 1-3-


Telephone numbers can be added or removed using the

-

keys.

Press the

key to switch to the other voice messages (B-D). Repeat

steps 3 and 4 for the remaining messages.

C> ---4


When the voice message has been allocated to the telephone number,
confirm by pressing

.

READY


Press

to end data entry.

10.8 Abort

If an alarm is triggered by accident and the dialer starts an alarm call,
then this can be aborted in a variety of ways. This function is used to
define which abort types are possible:

-

INPUT: Creation of a signal on the “ABORT TRIG”
input.

-

RESTORE: Removal of the trigger signal on the
input.

-

PASSCODE: Entry of the programming code.