beautypg.com

Extron Electronics SW 2_4 ARxi User Guide User Manual

Page 18

background image

SW ARxi

xi

xi

xi

xi and SW AR HVxi

xi

xi

xi

xi • Operation

SW ARxi

xi

xi

xi

xi and SW AR HVxi

xi

xi

xi

xi • Operation

SW ARxi

xi

xi

xi

xi and SW AR HVxi

xi

xi

xi

xi Operation, cont’d

Following are two examples of Switch DOS commands.

Example 1

Switch 254
Switch 255

Explanation:

Line 1: Switch to input 1, using default parameters.

Line 2: Clear the RS-232 2-4-6-8 buffer, using default
parameters.

Example 2

Switch 223 2 4800 8 2 N
Switch 255 2 4800 8 2 N

Explanation:

Line 1: Switch to input 6, using comm port 2 at 4800 baud,
8 data bits, 2 stop bits, no parity

Line 2: Clear the RS-232 2-4-6-8 buffer, using comm port 2
at 4800 baud, 8 data bits, 2 stop bits, no parity

You can create batch files to simplify input
selection.

Windows-compatible software

The RS-232 2-4-6-8 Control Program is used with SW ARxi
and SW AR HVxi switchers and the RS-232 2-4-6-8 adapter.
It is compatible with Windows 3.1, 3.11, 95/98, and NT.

Installing the software

The program is contained on a single 3.5-inch diskette, and
it can run from the floppy drive. However, it is usually
more convenient to load and run the program from the
hard drive.

To install the software from the floppy disk onto the hard
drive, run SETUP.EXE from the floppy disk, and follow the
instructions that appear on the screen.

By default, the Windows installation places two icons
(RS-232 2-4-6-8 Control Pgm and 2-4-6-8 ctrlr notes) into a
group or folder named “Extron Electronics”.

RS-232 2-4-6-8 adapter software

DOS and Windows® -compatible software, for controlling
SW ARxi and SW AR HVxi switchers through the
RS-232 2-4-6-8 adapter, is provided on a 3.5-inch diskette.
Both versions enable the switcher input number to be
selected from the host computer/device.

DOS-compatible software

The DOS version of software for SW ARxi and SW AR HVxi
switcher input selection is a program called "Switch". The
program can be run on the PC computer from the 3.5 inch
diskette, but it may be more convenient to copy the
program to the PC's hard drive. To copy Switch from the
diskette to the hard disk, do the following:

1.

Insert the 3.5 inch diskette into the PC's floppy disk

drive.

2.

At the DOS prompt, type the following command:

Copy A:\SWITCH.COM C:\

DOS command format for "Switch"

The DOS command format for Switch is:

SWITCH sc [cp br db sb pt]

Parameters are described in the table below.

Code Description

Selections

Defaults

sc

selection code

See table below

cp

comm port

Serial port number (1 - 4)

1

br

baud rate

300,600,1200,2400,4800,9600

4800

db

data bits

7 or 8

8

sb

stop bits

0, 1, 2

2

pt

parity type

N=None, E=Even, O=Odd

N

Input

Selection

Number

Code

1

254

2

253

3

251

4

247

5

239

6

223

Clear buffer

255

3-5

3-4