beautypg.com

Chapter three – Extron Electronics SW 2_4 ARxi User Guide User Manual

Page 16

background image

SW Switchers • Installation

Installation, cont’d

SW Switchers

3

Chapter Three

SW ARxi

xi

xi

xi

xi and SW AR HVxi

xi

xi

xi

xi

Operation

Operating Modes

Remote Operation

2-18

Troubleshooting

The sections below shows some common operating
problems and their solutions.

All models

Problem —

Pressing an input selection button does not

change the input.

Solution —

Verify the operating mode. The input

selection buttons do not change the input if the
switcher is in auto-switch mode or (for
SW AR MX, SW AR MX HV, and
SW 6 Component switchers only) auto-sequence
mode.

Problem —

Auto-switch does not work under composite

video, S-video, component video, or RGsB format.

Solution —

The sync portion of these video formats

must be connected to a video input and to the
H/S input through a T connector. See page 2-10.

SW AR MX, SW AR MX HV, and
SW 6 Component models

Problem —

You pressed input selection button 1, but the

input did not change, and one of the input/mode
selection LEDs is blinking (SW AR MX,
SW AR MX HV, and SW 6 Component switchers
only).

Solution —

Holding input selection button 1 for too

long causes the button to act as the front panel
mode selection button. To select an input, do not
hold the button after pressing it.

Problem —

The switcher is plugged into a functioning

power source, but does not turn on.

Solution —

Replace the fuse. See page 4-11.