beautypg.com

Installation, Tabletop placement, Rack mounting – Extron Electronics SEQ 100 15HD User Guide User Manual

Page 5: Ul requirements

background image

VersaTools

®

SEQ 100 Skew Equalizer

VersaTools

®

SEQ 00 Skew Equalizer, cont’d

VersaTools

®

SEQ 100 Skew Equalizer

POW

ER

12V

.5A

MA

X

INP

UT

OU

TPU

T

C

S

Y

N

C

S

O

G

C VIDE

O

N

/C

L

R

AU

DIO

OU

TP

UT

AV

IN

PU

T

RG

B

PO

WE

R

15V

.34

A M

AX

TP

T 15

HD A

H-S

HIFT

BUF

FER

ED

COM

PUT

ER

INPU

T

AUD

IO

ID PIN

4

ID

P

IN

1

1

LOC

AL M

ONIT

OR

Plasma/LCD

Display

Audio

Extron

TP T 15HD A

Twisted Pair

Transmitter

Extron

SEQ 100 15HD

Skew Equalizer

CAT5/5e/6

UTP Cable

Extron

TP R 15HD A

Twisted Pair

Receiver

PC

Figure 1 — Typical SEQ 100 BNC application

UTP cable test equipment measures and reports wire pair

length. The report on the various pair lengths can be used to set

the SEQ 100 to properly equalize pair skew.
If UTP cable test measurement cannot be done, pair skew can

still be equalized by viewing a test pattern with a critical eye.

Examine the test pattern for loss of horizontal registration and,

through a process of trial and error, equalize any pair skew with

the SEQ 100.
The SEQs are a part of the Extron VersaTools

®

line of basic

distribution amplifiers, switchers, transmitters, SEQs, and

associated video accessories. The rack- and furniture-mountable

equalizer has an external power suppy with worldwide

compatibility.

Installation

The 1U high, quarter rack width, SEQ 100 can be be placed on

a tabletop, mounted on a rack shelf, mounted to a rack without

a shelf, mounted under a desk or tabletop, or mounted on a

projector bracket.

Tabletop placement

Affix the four included rubber feet to the bottom of the unit and

place it in any convenient location.

Rack mounting

UL requirements

The following Underwriters Laboratories (UL) requirements

pertain to the installation of the SEQ into or onto a rack.
1

.

Elevated operating ambient

— If installed in a closed

or multi-unit rack assembly, the operating ambient

temperature of the rack environment may be greater

than room ambient. Therefore, consider installing the
equipment in an environment compatible with the +122 °F
(+50 °C) maximum ambient temperature (Tma) specified

by Extron.

2

.

Reduced air flow

— Installation of the equipment in a rack

should be such that the amount of air flow required for

safe operation of the equipment is not compromised.

3

.

Mechanical loading

— Mounting of the equipment in

the rack should be such that a hazardous condition is not

achieved due to uneven mechanical loading.

4

.

Circuit overloading

— Consideration should be given to

the connection of the equipment to the supply circuit and

the effect that overloading of the circuits might have on

overcurrent protection and supply wiring. Appropriate

consideration of equipment nameplate ratings should be

used when addressing this concern.

5

.

Reliable earthing (grounding)

— Reliable earthing

of rack-mounted equipment should be maintained.

Particular attention should be given to supply connections

other than direct connections to the branch circuit (such as

the use of power strips).