![background image](/manuals/312362/11/background.png)
VersaTools
®
SEQ 100 Skew Equalizer
VersaTools
®
SEQ 00 Skew Equalizer, cont’d
VersaTools
®
SEQ 100 Skew Equalizer
Connections
Connect the input device, output device, and the power supply
to the SEQ 100 Skew Equalizer (figure 12).
POWER
12V
.5A MAX
INPUT
OUTPUT
3
1
2
Figure 12 — SEQ 100 15HD rear panel features
a
Input connector (SEQ 100 15HD) —
Connect input VGA or
RGB video to this female 15-pin HD connector.
b
Output connector (SEQ 100 15HD) —
Connect a VGA or RGB
video device to this female 15-pin HD connector.
c
Power connector — Plug the included external 12 VDC power
supply into this 2-pole captive screw connector. Figure 13
shows how to wire the power connector.
SECTION A–A
Ridges
Smooth
2-Pole Orange
Captive Screw
Connector (12V)
Tie
Wrap
3/16”
(5 mm) Max.
Figure 13 — Power connector wiring
C
Power supply voltage polarity is critical. Incorrect
voltage polarity can damage the power supply and
the SEQ. Identify the power cord negative lead by
the ridges on the side of the cord (figure 13).
To verify the polarity before connection, plug in the power
supply with no load and check the output with a voltmeter.
W
The two power cord wires must be kept separate
while the power supply is plugged in. Remove
power before wiring.
C
The length of the exposed (stripped) copper wires
is important. The ideal length is 3/16" (5 mm).
Longer bare wires can short together. Shorter wires
are not as secure in the connectors and could be
pulled out.
N
Do not tin the power supply leads before installing them
in the connector. Tinned wires are not as secure in the
connectors and could be pulled out.
Use the supplied tie-wrap to strap the power cord to the
extended tail of the connector.
Alternatively, an optional Extron PS 123 Universal 12 VDC
Power Supply, part #60-814-01, can power multiple Extron
12 VDC devices using only one AC power connector.