beautypg.com

Wiring, Power, Control – Extron Electronics IPL 250 Setup Guide User Manual

Page 14: Wiring -4, Power -4 control -4, Setup, cont’d, Ipl 250 • setup, Ethernet/lan ( b ), Serial/rs-232 ( c , d ), Contact closure input ( g )

background image

Setup, cont’d

2-4

Refer also to the IPL 250 Reference Manual at www.extron.com.

IPL 250 • Setup

Power

Connect the

Extron 12 VDC,

1.0 A (max.)

power supply

to a as shown

here:

N

You must

use the supplied
Extron external 12 V,
1.0 A power supply.

Control

Ethernet/LAN (b)

RJ-45

Connector

Insert Twisted

Pair Wires

Pins:

12345678

Straight-through Cable

(for connection to a switch, hub, or router)

End 1

End 2

Pin

Wire Color

Pin Wire Color

1

white-orange

1

white-orange

2

orange

2

orange

3

white-green

3

white-green

4

blue

4

blue

5

white-blue

5

white-blue

6

green

6

green

7

white-brown

7

white-brown

8

brown

8

brown

Crossover Cable

(for direct connection to a PC)

End 1

End 2

Pin

Wire Color

Pin Wire Color

1

white-orange

1

white-green

2

orange

2

green

3

white-green

3

white-orange

4

blue

4

blue

5

white-blue

5

white-blue

6

green

6

orange

7

white-brown

7

white-brown

8

brown

8

brown

Tie

Wrap

Ridges

Smooth

Wiring

C

Installation and service must be performed by authorized personnel only.

Attach cables using the following wiring diagrams as a guide. Full details are

available in the IPL 250 Reference Manual.

Serial/RS-232 (c, d)

Wiring for COM 3 is the same as for

COM 2.

COM1

TX RX

RTS CTS

COM 2

TX RX

Tr

ansmit (Tx)

Receiv

e (Rx)

Ground (GND)

Tr

ansmit (Tx)

Receiv

e (Rx)

Ground (GND)

Request to send (R

TS)

Clear to send (CTS)

Strip wires

3/16”

(5 mm)

max.

Contact closure input (g)

INPUT

1 2 3 4

IPL 250
Rear Panel

Switch,

Sensor

2

1

3

4

Heat Shrink
Over Shield