Current sense

Range ...................................... 5 mA to 10 A
Resolution ............................... 0.1 mA steps from 5 mA to 99.9 mA

1 mA steps from 100 mA to 999 mA
10 mA steps from 1 A to 10 A

Tolerance ................................. ±20%

Alarm relay control

Quantity/type ................................. 1 normally open relay
Connector ...................................... (1) 3.5 mm captive screw connector, 2 pole
Contact rating ................................ 24 V, 1 A

General

Power input

IPL T PCS4 ............................... Internal

120 VAC, 50-60 Hz
15 watts

IPL T PCS4i ............................... Internal

220 VAC, 50-60 Hz
15 watts

Temperature/humidity .................... Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing

Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing

Cooling .......................................... Convection, no vents
Mounting

Rack mount ............................. Yes, with optional 1U rack shelf
Furniture mount ...................... Yes, under-furniture mountable with optional mounting kit

Enclosure type ................................ Metal
Enclosure dimensions ..................... 1.7" H x 8.7" W x 9.5" D (1U high, half rack wide)

(4.3 cm H x 22.0 cm W x 24.1 cm D)
(Depth excludes connectors.)

Product weight ............................... 2.6 lbs (1.2 kg)
Shipping weight ............................. 5 lbs (3 kg)
Vibration ........................................ ISTA 1A in carton (International Safe Transit Association)
Regulatory compliance

Safety

IPL T PCS4 .......................... CE, c-UL, UL
IPL T PCS4i ......................... CE

EMI/EMC ................................. CE, C-tick, FCC Class A, ICES, VCCI

MTBF ............................................. 30,000 hours
Warranty ........................................ 3 years parts and labor