Command and Response Table for SIS Commands
Command
ASCII (Telnet)
(Host to Switcher)
URL Encoded (Web)
(Host to Switcher)
Response
(Switcher to Host)
Power Receptacle Control / Current Sense
Turn receptacle power on
E
X!
*1PC
}
W
X!
%2A 1PC
|
Cpn
X!•
Ppc1
]
Turn receptacle power off
E
X!
*0PC
}
W
X!
%2A 0PC
|
Cpn
X!•
Ppc0
]
View receptacle power status
E
X!
PC
}
W
X!
PC
|
X%
]
Query receptacle current status
E
X!
PS
}
W
X!
PS
|
X(
]
Group receptacles
E
X1)
1
X1)
2
X1)
3
X1)
4
GP
}
W
X1)
1
X1)
2
X1)
3
X1)
4
GP
|
Pgp
X1)
1
X1)
2
X1)
3
X1)
4
]
Ungroup receptacles
E
0000GP
}
W 0000GP
|
Pgp0000
]
View receptacles grouping
E
GP
}
W GP
|
X1)
1
X1)
2
X1)
3
X1)
4
]
Set power up delay
E
X1^
DT
}
W
X1^
DT
|
Pdt
X1^
]
View power up delay
E
DT
}
W DT
|
X1^
]
Set individual full threshold
E
X!
*2TH
}
W
X!
%2A 2TH
|
Ptf
X!
]
Set individual standby threshold
E
X!
*1TH
}
W
X!
%2A 1TH
|
Pts
X!
]
Clear individual threshold
E
X!
*0TH
}
W
X!
%2A 0TH
|
Ptc
X!
]
View threshold setting for all ports
E
TH
}
W TH
|
X(
1
,X(
2
,X(
3
,X(
4
]
Set Executive mode on
1X
1X
Exe1
]
Set Executive mode off
0X
0X
Exe0
]
View Executive mode
X
X
X%
]
Power Receptacle Monitoring and Alarm Functions
Set alarm conditions
E
X!
*
X70!
*
X70@
*
X70#
SA
}
W
X!
%2A
X70!
%2A
X70@
%2A
X70#
SA
|
Ast
X!
*
X70!
*
X70@
*
X70#
*
X70$
*
X70%
]
View alarm conditions
E
X!
*SA
}
W
X!
SA
|
X70!
*
X70@
*
X70#
*
X70$
*
X70%
]
Monitoring enable or disable
E
X!
*
X70$
SA
}
W
X!
%2A
X70$
SA
|
Ast
X!
*
X70!
*
X70@
*
X70#
*
X70$
*
X70%
]
Set Alarm mode
E
X70^
*
X70&
*
X70*
*
X70*
*
X71)
MA
}
W
X70^
%2A
X70&
%2A
X70*
%2A
X70*
%2A
X71)
MA
|
Arl
X70^
*
X70&
*
X70*
*
X70*
*
X71)
]
View Alarm mode
E
MA
}
WMA
|
X70^
*
X70&
*
X70*
*
X70*
*
X71)
]
Power Receptacle Scheduling
Set scheduling
E
X!
*
X71!
*
X%
*
X71@
SS
}
W
X!
%2A
X71!
%2A
X%
%2A
X71@
SS
Set
X!
*
X71!
*
X%
*
X71@
]
View scheduling
E
X!
*
X71!
*
X%
SS
}
W
X!
%2A
X71!
%2A
X%
SS
|
X71@ ]
Alarm Relay Functions
Turn alarm relay ON
1*1O
}
1 %2A 1O
|
Cpn1
•
Rly1
]
Turn alarm relay OFF
1*0O
}
1 %2A 0O
|
Cpn1
•
Rly0
]
View alarm relay state
1O
}
1O
|
X%
]
Pulse relay
1*3*
X6#
O
}
1 %2A 3 %2A
X6#
O
|
Cpn1
•
Rly1
]
or
Cpn1
•
Rly0
]
Toggle relay
1*2O
}
Cpn1
•
Rly1
]
or
Cpn1
•
Rly0
]
Ethernet Data Port Commands
Set current connected port
timeout
E
0*
X6(
TC
}
W0 %2A
X6(
TC
|
Pti0*
X6(
]
View current connected port
timeout
E
0TC
}
W0TC
|
X6(
]
Set global IP port timeout
E
1*
X6(
TC
}
W1 %2A
X6(
TC
|
Pti1*
X6(
]
View global IP port timeout
E
1TC
}
W1TC
|
X6(
]