Delay Menu (for Triple-Action™ Switching)
Press any menu title
button at any time
to “escape” without
making changes.
To get here from the Main Menu,
press:
• Delay
Instruction message appears here >
Use option selections with buttons >
Figure 3-9. Delay menu (not available with composite or S-video)
As explained on Page 3-9, the 3200/6400 Wideband Matrix systems have Triple-
Action Switching. The Delay menu displays the delay time settings for each
output. The delay time can be set for from 0 to 5 seconds in steps of 0.5 second.
Use the scroll buttons (
), or the speed knob (
) to select the output to be
adjusted.
A d j u s t
Press Adjust to change the delay time for the selected output. Use the scroll
buttons (
), or the speed knob (
) to adjust the delay time for the selected
output and then press one of the buttons described below, or press ESC to go
back.
T a k e
Press Take to save the changes or ESC to exit without saving changes.
G l o b a l
This button sets the delay values for all outputs to be the same as the one
selected. For example, you may select an output, adjust its delay for 1.5 seconds
and press Global. All output delays will be 1.5 seconds.
D e f a u l t
This button resets all output delays to a delay time of 0.0 seconds. This is also
the “factory default”.
After pressing Take, Global or Default, a warning message appears to confirm
the action. Press Take (again) to accept the changes.
Set Switching Delay