beautypg.com

Appendix: av9 serial programming interface, Data transfer format, Setting values – Arcam FMJ AV9 User Manual

Page 41: Query commands, Command processing

background image

AV9

E-40

E

n

g

li

s

h

AV9

E-41

Appendix: AV9 serial programming interface

This section of the document details the serial command set of the AV9 software.

Data transfer format

<

Transfer rate: 38,400bps.

<

1 start bit, 8 data bits, 1 stop bit, no parity, no flow control.

Command lines must be terminated by an ASCII line feed (0x0A hexadecimal) and be no longer than
64 bytes (including the line feed terminator).
For example: to turn zone 1 on, send:

Z1PWR1

where

is an ASCII line feed.

Setting values

As well as setting options directly to specific values, as described above, current values may be
incremented or decremented by following the command with a

+ (increment) or (decrement). For

example, to increment the decode mode in zone 1:

Z1DEC+

If a zone is not specified, the command is carried out in relation to zone 1. For example, to decrement
the THX mode:

Z1THX-

would produce identical results to using:

THX-

Multiple commands may be placed on a single command line if separated by a semicolon. For example,
to turn on zone 1 and switch to the tuner, use:

Z1PWR1;Z1AUD2

Query commands

The current values of a small subset of settings may be queried, by preceding the command with a

?.

For example, to query the mute status of Zone 2, use:

?Z2MUT

If Zone 2 mute is ON, the AV9 responds with the message:

Z2MUT1

This response gives the zone it is reporting on (

Z2 in this case), the setting (MUT), and the current value

(a

1, showing it as ON).

In order to keep the RS232 controller informed of the current state of the AV9, certain changes in
configuration/state will result in the AV9 automatically sending messages, just as if they had been
queried using the method above. Changes in the following items will result in an RS232 response:

<

Zone Status

<

THX Mode

<

Zone 1 Audio

<

Zone 1 Volume

<

Zone 1 Video

<

Audio Signal Type

<

Decode Mode

<

Current Preset

<

Effect Mode

<

Direct Mode

Command processing

Command processing begins when the first semicolon separator of line feed terminator is received. If
there is an error in the command an error message

FAIL is sent back. If the command is executed

successfully, the command is echoed back to the sender.
In the command tables below, one or more of the following parameters may be used:

Param.

Description

?

Query Option. The value can be queried by putting a

? before the command.

z

Zone selection. The zone can be selected by putting a

z before the command. Values are Z1 (for zone 1) or

Z2 (for Zone 2).

x

On/Off, Yes/No. The value can be set by putting an

x after the command. Values are 1 (for On/Yes) or 0 (for

Off/No).

y

Value. The value can be set by putting a

y after the command. Values have various ranges, as described in

the tables below.

i

Input Source. The source can be set by putting an

i after the command. Values are in the range 0 to 9,A,B

as follows:
0 = None/Not Connected, 1 = Source, 2 = AUX, 3 = CD, 4 = TUNER, 5 = DVD, 6 = SAT,

7 = AV, 8 = MULTICHANNEL, 9 = TAPE, A = VCR, B = Follow Zone 1.

s

Channel/Speaker Select. Values are in the range

0 to 8 as follows:

0 = Centre, 1 = Front Left, 2 = Front Right, 3 = Surr. Left, 4 = Surr. Right,

5 = Surr. Back Left, 6 = Surr. Back Right, 7 = Subwoofer, 8 = All/Master.