beautypg.com

8 cable gland liquid-tight connections – Xylem FM500 ULTRASONIC FLOW METERS User Manual

Page 19

background image

Page 19

The SPU wiring compartment is equipped with:
six large liquid-tight cable gland connectors,
two small

2 each for the transducer cables
3 each for the process control relay connection cables

The blank grommet plug should be used when the

liquid-tight cable gland connectors, and

a communications cable liquid-tight cable gland grommet and plug.

To ensure that the SPU enclosure remains water-tight, the following cable glands should
be used:

The six large liquid-tight connectors can be used with any cable diameter from .200
to .394 inches (5.1 to 10.0 mm). They are provided for:
1 each for the power input cable

The two small liquid-tight connectors can be used with any cable diameter from .118
to .255 inches (3.0 to 6.5 mm). They are provided for:
1 each for the 4-20 mA output signal cable
1 each for the pulse output signal cable

The communications cable grommet can be used with any cable diameter from .190
to .205 inches. It is provided for any one of the following cable types:
USB cable
Ethernet Cable
RS-232 serial cable
RS-485 serial cable

communications cable grommet is

not required.

3.8
Cable Gland
Liquid-Tight
Connections

5k

5-30 VDC

Frequency output (0-1000 Hz)

Open Collector output, 50% duty cycle

Current

input

Current

output

4-20mA receiver

Flow Meter

Current output (4-20 mA)

Maximum load 1000 ohms

Digital Pulse Receiver

Flow Meter

Frequency

input

Ground

1

2

3

4

5

Signal Output
Terminal Block

SIGNAL OUTPUT CONNECTIONS

Neutral

input

Line

intput

110 to 240 VAC 50/60Hz

40 WATTS MAX

15 to 30 VDC

40 WATTS MAX

Flow Meter

Positive

(+)

Negative

(-)

1

2

3

4

5

Power Input
Terminal Block

POWER INPUT CONNECTIONS

(Open Collector output

50% duty cycle)

Ultrasonic Flowmeter