beautypg.com

Setup root menu – Xylem FM500 ULTRASONIC FLOW METERS User Manual

Page 14

background image

Page 14

Setup Root Menu

Manage Configuration Sets

Ê

Create a New Configuration Set

Configuration Set #1

К

К

Transducer Setup

Ê

Transducer

Pipe

Liner

Measurement Units

Fluid

Ê

Mount Method

К

К

Outside Diameter

Ê

Wall Thickness
Pipe Material

К

К

К

К

Speed of Sound in Custom material

К

К

Delete a Saved Configuration Set

Ê

Activate a Configuration Set

Ê

Open a Saved Configuration Set

Configuration Set #2

Ê

Configuration Set #3

Ê

Configuration Set #4

Ê

Configuration Set #5

К

К

К

Metric (SI units)

English (U.S. units)

Ê

Model Number

Ê

Cable Length (Feet)

Liner Wall Thickness

Ê

Speed of Sound in Liner material

Ê

Fluid Type

Ê

Speed of Sound in Custom Fluid

К

К

Metering Setup

Flow Rate

Ê

Volume Units

Ê

Custom Unit Volume per U.S. Gallon

Time Units

К

К

Digits After Decimal Point

Ê

Totalizer

Ê

Volume Units

Ê

Custom Unit Volume per U.S. Gallon

Total Display Function

К

К

Digits After Decimal Point

Ê

Display

Ê

Display Language

Ê

Flow Rate Averaging

Low Flow Cutoff

К
К

Display Update

Ê

Scaling Offset

Ê

High Flow Cutoff

Ê

Signal Output

Ê

Analog Output

Ê

Pulse Output

Ê

Data Logging

Ê

Log Interval

Ê

Log Rate Setpoint

К

К

Log Totalizer Setpoint

Ê

Process Control Setup

Relay Channel #1

Ê

Assign Relay

Ê

Monitor Flow Rate

Ê

Monitor Flow Total

Ê

Disabled

Ê

Flow Rate Alarm Settings

Ê

High Trigger

Ê

High Release

Ê

Low Trigger

Ê

Low Release

Ê

Alarm Delay Time

Ê

Batch Dispense Settings

Ê

Default Batch Amount

Ê

Batch Start Mode

Ê

Relay Timer

К

К

К

Relay Channel #2

Ê

Assign Relay

Ê

Monitor Flow Rate

Ê

Monitor Flow Total

Ê

Disabled

Ê

Flow Rate Alarm Settings

Ê

High Trigger

Ê

High Release

Ê

Low Trigger

Ê

Low Release

Ê

Alarm Delay Time

Ê

Batch Dispense Settings

Ê

Default Batch Amount

Ê

Batch Start Mode

Ê

Relay Timer

К

К

К

Relay Channel #3

Ê

Assign Relay

Ê

Monitor Flow Rate

Ê

Monitor Flow Total

Ê

Disabled

Ê

Flow Rate Alarm Settings

Ê

High Trigger

Ê

High Release

Ê

Low Trigger

Ê

Low Release

Ê

Alarm Delay Time

Ê

Batch Dispense Settings

Ê

Default Batch Amount

Ê

Batch Start Mode

Ê

Relay Timer

К

К

К

Global Configuration

Ê

Communications Settings

Ê

Master Password

Ê

Date and Time

Ê

Save Changes

Manual Batch Start
Auto (Proportional)

Manual Batch Start
Auto (Proportional)

Manual Batch Start
Auto (Proportional)

Ultrasonic Flowmeter