beautypg.com

Configure the meter (continued), Page 13, Highlight transducer and press enter – Xylem FM500 ULTRASONIC FLOW METERS User Manual

Page 13: Highlight pipe and press enter, Highlight pipe material and press enter, Highlight fluid and press enter, Highlight fluid type and press enter, Highlight the actual fluid type and press enter

background image

ENTER

Ç

ESC

È

Configuration Set #1

Transducer Setup
Metering Setup

Process Control Setup
Reset Working Set to Fact. Defaults
Set Password...
Save
Save As ...

Save and Activate

ENTER

Ç

ESC

È

Configuration Set #1

Ê

Pipe

Transducer Setup

Wall Thickness

0.218

К

К

ENTER

Ç

ESC

È

Configuration Set #1

Ê

Pipe

Transducer Setup

Outside Diameter

Pipe Material

Wall Thickness

Speed of Sound in Custom Material

Page 13

6

Configure the meter (continued)

ENTER

Ç

ESC

È

Configuration Set #1

Transducer Setup

Metering Setup
Process Control Setup
Reset Working Set to Fact. Defaults
Set Password...
Save
Save As ...
Save and Activate

5. Highlight Transducer
Setup
and press enter.

7. Highlight Mount
Method
and press enter.

ENTER

Ç

ESC

È

Configuration Set #1

Ê

Transducer

Ê

Transducer Setup

V

Mount Method

W
Z

N

8. Highlight a Mount
Method
and press enter.

9. Press escape.

ENTER

Ç

ESC

È

Configuration Set #1

Ê

Transducer

Ê

Transducer Setup

Model Number

Cable Length (Feet)

Mount Method

Ê

ENTER

Ç

ESC

È

Configuration Set #1

Ê

Transducer

Ê

Transducer Setup

Model Number

Cable Length (Feet)

Mount Method

Ê

ENTER

Ç

ESC

È

Configuration Set #1

Ê

Transducer

Ê

Transducer Setup

Measurement Units

Pipe

Transducer

Liner

Fluid

Ê

6. Highlight Transducer
and press enter.

ENTER

Ç

ESC

È

Configuration Set #1

Transducer Setup

Measurement Units

Pipe

Transducer

Liner

Fluid

Ê

10. Highlight Pipe and
press enter.

ENTER

Ç

ESC

È

Configuration Set #1

Ê

Pipe

Transducer Setup

Outside Diameter

Pipe Material

Wall Thickness

Speed of Sound in Custom Material

Ê

ENTER

Ç

ESC

È

Configuration Set #1

Ê

Pipe

Transducer Setup

Outside Diameter

2.625

К

К

11. Highlight Outside
Diameter
and press
enter.

12. Input the actual
outside diameter and
press enter.

ENTER

Ç

ESC

È

Configuration Set #1

Ê

Pipe

Transducer Setup

Outside Diameter

Pipe Material

Wall Thickness

Speed of Sound in Custom Material

Ê

ENTER

Ç

ESC

È

Configuration Set #3

Ê

Pipe

Ê

Pipe Material

Ê

PVDF

Transducer Setup

PVC/CPVC

Stainless Steel 302/303
Stainless Steel 304
Stainless Steel 304L
Stainless Steel 316

И

И

К

13. Highlight Wall
Thickness
and press
enter.

14. Input the actual wall
thickness and press
enter.

16. Highlight the actual
Pipe Material and press
enter.

17. Press escape.

ENTER

Ç

ESC

È

Configuration Set #1

Ê

Pipe

Transducer Setup

Outside Diameter

Pipe Material

Wall Thickness

Speed of Sound in Custom Material

Ê

15. Highlight Pipe
Material
and press
enter.

ENTER

Ç

ESC

È

Configuration Set #1

Transducer Setup

Measurement Units

Pipe

Transducer

Liner

Fluid

Ê

18. Highlight Fluid and
press enter.

ENTER

Ç

ESC

È

Configuration Set #1

Transducer Setup

Fluid

Speed of Sound in Fluid Type

Fluid type

К

К

19. Highlight Fluid Type
and press enter.

ENTER

Ç

ESC

È

Configuration Set #1

Transducer Setup

Fluid

Water (Waste, Distilled)

Fluid type

К

К

К

1, 1, 1, Trichloroethane

1-Propanal
Acetone (Dimethyl ketone, 2-Propanone)

Custom

Alcohol (Ethyl alcohol, Ethanol)

И

И

20. Highlight the actual
Fluid Type and press
enter.

ENTER

Ç

ESC

È

Configuration Set #1

Transducer Setup

Fluid

Speed of Sound in Fluid Type

Fluid type

К

К

21. Press escape twice.

22. Highlight Save and
Activate
and press enter.

Position the transducers
at a separation distance of:

Transducer Positioning …

0.884416 inches (”V” Mount)

Firmware Version, A01.00.00

Press DONE when this is complete

DONE

Information Screen

23. Position the
Transducers on the pipe
and press Done.

Ultrasonic Flowmeter