B. INTENSIFIER TUBE REPLACEMENT MANUAL

The intensifier tube can be removed or installed without disassembling the unit’s wired housing. Re-

moving or installing the intensifier tube only requires the removal of the eyepiece. The airtight seal

will be broken, and the final assembly must be purged with nitrogen to eliminate moisture within the

monocular.

B.1 INITIAL SETUP

A. Test Facility
Clean station in the electronic repair service area.

B. Tools
None

C. Materials/Parts
Intensifier Tube
Cotton-tipped applicators
Isopropyl alcohol

WARNING:

The intensifier’s phosphor screen contains toxic materials!
— If an intensifier tube breaks, be extremely careful to avoid inhaling the phosphor screen

material. DO NOT allow the material to come in contact with the mouth, eyes, or open wounds

on the skin.
— If the phosphor screen material contacts your skin, wash it off immediately with soap and

water.
— If you inhale or swallow any phosphor screen material, drink a lot of water, induce vomiting,

and seek medical attention as soon as possible.

NOTE:

Before replacing the intensifier tube, confirm that it is out of the warranty period.

B.2 PROCEDURE OF INTENSIFIER TUBE REPLACEMENT

1. Unscrew the eyepiece (E) from the unit body (A).
2. Unscrew the lock ring (D) from the unit body (A).
3. Extract the light guide (C) from the unit body (A).