Test Configurations
Note: Measure input reflected-ripple current with a simulated 
source inductance (LTEST) of 12 µH. Capacitor CS offsets 
possible battery impedance. Measure current as shown above. 
Figure 11. Input Reflected Ripple Current Test Setup. 
 
Note: Use a 1.0 µF ceramic capacitor, a 10 µF aluminum or 
tantalum capacitor and a 750µF polymer capacitor. Scope 
measurement should be made using a BNC socket. Position the 
load between 51 mm and 76 mm (2 in. and 3 in.) from the module. 
Figure 12. Output Ripple and Noise Test Setup.
Note: All measurements are taken at the module terminals. When 
socketing, place Kelvin connections at module terminals to avoid 
measurement errors due to socket contact resistance.
Figure 13. Output Voltage and Efficiency Test Setup.
Design Considerations
Input Source Impedance
The power module should be connected to a low
ac-impedance source. Highly inductive source impedance 
can affect the stability of the power module. For the test 
configuration in Figure 11, a 660μF electrolytic capacitor, C
in
,
(ESR<0.7 at 100kHz), mounted close to the power module 
helps ensure the stability of the unit. 
Safety Considerations
For safety-agency approval of the system in which the 
power module is used, the power module must be installed 
in compliance with the spacing and separation 
requirements of the end-use safety agency standard, i.e., 
UL60950-1 2
nd
Ed., CSA C22.2 No. 60950-1 2
nd
Ed., and
VDE0805-1 EN60950-1 2
nd
Ed.
If the input source is non-SELV (ELV or a hazardous voltage 
greater than 60 Vdc and less than or equal to 75Vdc), for the 
module’s output to be considered as meeting the 
requirements for safety extra-low voltage (SELV), all of the 
following must be true: 
 
The input source is to be provided with reinforced 
insulation from any other hazardous voltages, including 
the ac mains.
One V
IN
pin and one V
OUT
pin are to be grounded, or
both the input and output pins are to be kept floating.
The input pins of the module are not operator 
accessible. 
Another SELV reliability test is conducted on the whole 
system (combination of supply source and subject 
module), as required by the safety agencies, to verify 
that under a single fault, hazardous voltages do not 
appear at the module’s output. 
Note: Do not ground either of the input pins of the module
without grounding one of the output pins. This may 
allow a non-SELV voltage to appear between the 
output pins and ground. 
The power module has safety extra-low voltage (SELV) 
outputs when all inputs are SELV. 
The input to these units is to be provided with a maximum 
30A fast-acting (or time-delay) fuse in the ungrounded input 
lead. 
 
 
LOAD
CONTACT AND
SUPPLY
I
I
CONTACT
V
I
(+)
V
I
(–)
V
O1
DISTRIBUTION LOSSES
RESISTANCE
I
O
V