GE
Data Sheet
40A Digital MegaDLynx
TM
: Non-Isolated DC-DC Power Modules
4.5Vdc –14.4Vdc input; 0.45Vdc to 2.0Vdc output; 40A Output Current
April 24, 2013
©2012 General Electric Company. All rights reserved.
Page 21
STATUS_TEMPERATURE: Returns one byte of information
relating to the status of the module’s temperature related
faults.
Bit Position
Flag
Default
Value
7
OT Fault
0
6
OT Warning
0
5
X
0
4
X
0
3
X
0
2
X
0
1
X
0
0
X
0
STATUS_CML : Returns one byte of information relating to the
status of the module’s communication related faults.
Bit Position
Flag
Default
Value
7
Invalid/Unsupported Command
0
6
Invalid/Unsupported Command
0
5
Packet Error Check Failed
0
4
X
0
3
X
0
2
X
0
1
Other Communication Fault
0
0
X
0
MFR_VIN_MIN : Returns minimum input voltage as two data
bytes of information in Linear format (upper five bits are
exponent – fixed at -2, and lower 11 bits are mantissa in
two’s complement format – fixed at 12)
MFR_VOUT_MIN : Returns minimum output voltage as two
data bytes of information in Linear format (upper five bits are
exponent – fixed at -10, and lower 11 bits are mantissa in
two’s complement format – fixed at 614)
MFR_SPECIFIC_00 : Returns information related to the type of
module. Bits [7:2] in the Low Byte indicate the module type
(000100 corresponds to the MDT040 series of module). Bits
1:0 in the High Byte are used to indicate the manufacturer ID,
with 00 reserved for GE.
Low Byte
Bit Position
Flag
Default
Value
7:2
Module Name
000100
1:0
Reserved
10
High Byte
Bit Position
Flag
Default
Value
7:0
Module Revision Number
None
1:0
Manufacturer ID
00