Data sheet, Electrical specifications, General specifications – GE Industrial Solutions QBDW033A0B Barracuda Series User Manual
Page 3
GE
Data Sheet
QBDW033A0B Barracuda Series; DC-DC Converter Power Modules
36-75Vdc Input; 12.0Vdc, 33.0A, 400W Output
May 9, 2013
©2012 General Electric Company. All rights reserved.
Page 3
Electrical Specifications
(continued)
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
Parameter
Device
Symbol
Min
Typ
Max
Unit
Output Voltage Set-point (Default)
(V
IN
=V
IN,nom
, I
O
=16.5A, T
A
=25°C)
(Adjustable via PMBus)
All V
O, set
11.97 12.00 12.03 V
dc
Output Voltage Variation from Default
(Over all operating input voltage (40V to 75V), resistive
load, and temperature conditions until end of life)
All w/o -
P
V
O
11.76
12.24
V
dc
-P
Option
V
O
11.63
12.37 V
dc
Output Voltage (V
IN
=36V, T
A
= 25ºC)
All
V
O
11.00
V
dc
Output Regulation [V
IN, min
= 40V]
Line (V
IN
= V
IN, min
to V
IN, max
) All
0.2
% V
O, set
Load (I
O
=I
O, min
to I
O, max
)
All w/o -
P
0.2
% V
O, set
Load (I
O
=I
O, min
to I
O, max
), Intentional Droop
-P
O ti
0.50
V
dc
Temperature (T
A
= -40ºC to +85ºC)
All
2
% V
O, set
Output Ripple and Noise on nominal output
(V
IN
=V
IN, nom
and I
O
=I
O, min
to I
O, max
)
RMS (5Hz to 20MHz bandwidth)
All
70
mV
rms
Peak-to-Peak (5Hz to 20MHz bandwidth)
All
200
mV
pk-pk
External Output Capacitance
For C
O
>5000uF, I
O
must be < 50% I
O, max
during T
rise
.
All C
O, max
0
10,000
μF
Output Current
All
I
O
0 33
A
dc
VOUT_OC_FAULT_LIMIT (Default)
(Adjustable via PMBus)
All I
O,lim
40
A
dc
Efficiency
V
IN
=V
IN, nom
, T
A
=25°C
I
O
=100% I
O, max,
V
O
= V
O,set
All
η
95.3
%
I
O
=40% I
O, max
to 75% I
O, max ,
V
O
= V
O,set
All
η
95.8
%
Switching Frequency
f
sw
150 kHz
Dynamic
Load
Response
dI
O
/d
t
=1A/10s; V
in
=V
in
,
nom
; T
A
=25°C;
(Tested with a 1.0μF ceramic, a 10μF tantalum, and
470μF capacitor and across the load.)
Load Change from I
O
= 50% to 75% of I
O,max
:
Peak Deviation
Settling Time (V
O
<10% peak deviation)
All
V
pk
t
s
__
500
700
__
mV
pk
s
Load Change from I
O
= 75% to 50% of I
O,max
:
Peak Deviation
Settling Time (V
O
<10% peak deviation)
All
V
pk
t
s
__
__
500
700
__
mV
pk
s
General Specifications
Parameter
Device
Symbol
Typ
Unit
Calculated Reliability Based upon Telcordia SR-332 Issue
2: Method I, Case 3, (I
O
=80%I
O, max
, T
A
=40°C, Airflow = 200
LFM), 90% confidence
All
MTBF
3,108,685
Hours
All FIT
321.7
10
9
/Hours
Weight – Open Frame
47.4 (1.67)
g (oz.)
Weight – with Base plate option
66.4 (2.34)
g (oz.)