Installing the Flux Shifter
1. Carefully rotate the breaker onto its back so that the
bottom of the breaker is accessible.
NOTE: If the breaker has already been converted to
solid state trip devices, the existing trip actuator and
linkage must be removed and discarded.
2. Remove and retain the left front rack mounting bolt
on the breaker frame. The head of the bolt has a
radial slot cut into it. Slide the new flux shifter
assembly in through the bottom of the breaker, as
shown in Figure 22 for 225–800 A breakers and in
Figure 23 for 1600 A breakers. Align the bracket with
the hole in the frame from which the mounting bolt
was removed. Reinsert the mounting bolt through the
hole in the frame.
3. On 225–800 A breakers, insert the
1
/
4
-20 x
1
/
2
" bolt
and lock washer provided through the hole behind
the rack mounting bolt. The bolt is threaded into a
tapped hole in the mounting bracket, as shown in
Figure 22.
On 1600 A breakers, the
1
/
4
-20 x
1
/
2
" bolt is inserted
through a hole in front of the rack mounting bolt, as
shown in Figure 23. On some older versions, a #8-32
x
1
/
2
" screw, lock washer, and nut are used instead
of the
1
/
4
-20 bolt.
4. Ensure that the reset arm linkage is on the inside of
the crossbar arm. Line up the hole in the reset arm
with the hole in the crossbar, as shown in Figure 24.
Insert the
1
/
4
" x
3
/
4
" pin provided through the large
hole in the side of the breaker frame. Place the two
washers and the cotter pin provided on the other end
of the pin.
NOTE: If an auxiliary switch is mounted on the left side
of the breaker, the auxiliary switch operating arm must
be modified. Drill out the pin that is connected to the
crossbar arm with a 0.257"-diameter drill. Place the end
of the link over the pin inserted through the crossbar
arm and reset link. Use only one washer and the cotter
pin.
Figure 22. Flux shifter installation, 225–800 A breakers.
Figure 23. Flux shifter installation, 1600 A breakers.
Figure 24. Reset linkage assembly.