GE Industrial Solutions A-Series II Panelboards TQD User Manual
A-series, Ii panelboards
DEH40152
DEH40152 Rev.No.02
1
g
A-Series
®
II Panelboards
AD/AE/AQ Type P & N Power Panel
TQD Three-Phase Circuit Breaker
Kits
Introduction
These instructions describe the installation of TQD three-phase circuit breaker kit into an
A-Series
®
II panelboard. These kits are for use in panelboards ordered with Un-Specified
Space. The catalog number for six-pole TQD breaker kit is ASPP6QD6D
Parts List for ASPP6QD6D Table 1.
ITEM #
DESCRIPTION
PART #
QTY
1
BRANCH BASE FOR B PHASE
139C5702BQDG1
1
2
BRANCH BASE FOR A PHASE
139C5702AQDG1
1
3
BRANCH BASE FOR C PHASE
139C5702CQDG1
1
4 (SPOOL)
315A7036P19
6
5 (SCREW-SPOOL)
315A7037P4
6
6 (WASHER-SPOOL)
75A105503P111 6
7 (SCREW-BUS)
315A7034P8
6
8 3P
BRACKET
139C5500P81
2
9
SCREW, BKT TO RAIL
N667P16008B6
8
10
SCREW, C/B TO BKT
N80P150046B6
4
11
FILLER PLATE, TQD
139C5503P64
1
12
SCREWS , #10-32 X 3/8
N722P16006B6
4
13 NUT
N210P16B6
6
14 CUP
WASHER
254V644P1
4
Installation
WARNING: Before attempting to install one of these kits, remove all power from the
panelboard.
Use the following procedure to install a TQD circuit breaker kit. Call-out numbers in the
illustrations and numbers in brackets in the text refer to the Item Numbers in Table 1.
Installation of a three-pole kit is illustrated in Figure 1.
1. Remove the interior assembly from its packaging and verify that all parts are
present, as given in the parts list.
2. Remove the 8 screws (600A and 800A panels) securing the dead front to
panelboard interior. Lift off the dead front and place it and the screws aside.
3. Remove the circuit breaker kit from its packaging and verify that all parts are
present, as given in the packing list.