Characteristic Curves (continued)
The following figures provide typical characteristics for the CAR0812DC converter at 25
o
C
CU
RRE
NT
V
O
(V
) (20
0mV/d
iv)
I
O
(I) (2
0A/d
iv)
V
O
(V
) (2
0m
V/div)
I
O
(I)
(5
00
mA/
div)
TIME, t (2ms/div)
TIME, t (50ms/div)
Figure 7. 12V transient response for 10 to 60% step load,
Vin: -48V
DC
, slew rate 1A/µs.
Figure 7. 12V transient response for 10 to 60% step load, Vin:
-48V
DC
, slew rate 1A/µs.
Vout
Iout
Iout
Total (A)
Iout
unit #1 (A)
Iout
unit #2 (A) Ishare
11.968
25%
35.47
18.54
16.93
1.13%
11.96
30%
42.51
22.07
20.44
1.15%
11.923
50%
70.4
36.09
34.31
1.25%
11.877
75%
106
54.25
51.75
1.76%
11.831
100%
140.86
71.65
69.21
1.72%
Vout
Iout
Iout
Total (A)
Iout
DC unit (A)
Iout
AC unit (A) Ishare
11.972
25%
35.32
17.71
17.61
0.07%
11.965
30%
42.4
21.43
20.97
0.32%
11.925
50%
69.91
34.07
35.84
1.25%
11.878
75%
104.74
50.81
53.93
2.20%
11.831
100%
140.09
68.99
71.1
1.49%
Vin = 48Vdc
Vin = 48Vdc
Table 9. Current share accuracy among two CAR0812DC
units
Table 10. Current share accuracy among a CAR0812AC and a
CAR0812DC unit
(-10°C)
25°C
50°C
Turn ON point (V)
35
34.9
34.9
Turn OFF point (V)
32.7
32.7
32.7
Hysteresis (V)
2.3
2.2
2.2
NO LOAD
(-10°C)
25°C
50°C
Turn ON point (V)
35.8
35.6
35.5
Turn OFF point (V)
33.3
33.5
33.4
Hysteresis (V)
2.5
2.1
2.1
FULL LOAD
Table 11. Input under voltage protection – no load
Table 12. Input under voltage protection – full load
RT3 (actual temperature)
Full load 50°C ambient
75°C
Half load 70C ambient
79.1C
Protect point
95C
Recovery point
79C
Table 13. Over-temperature protection; Actual temperature