Car0812dc series dc-dc converter, Data sheet, Input: -36v – GE Industrial Solutions CAR0812DC Series User Manual
Page 6: Output: +12 v, Or 5 v, Environmental specifications, Emc compliance
GE
Data Sheet
CAR0812DC Series DC-DC Converter
Input: -36V
DC
to -75V
DC
; Output: +12 V
DC
@ 850W; 3.3V
DC
or 5 V
DC
@ 1A
April 23, 2013
©2013 General Electric Company. All rights reserved.
Page 6
Environmental Specifications
Parameter
Min
Typ
Max
Units
Notes
Ambient Temperature
-10
5
70
°C
Derated above 50C
Storage Temperature
-40
85
°C
Operating Altitude
2250/7382
m/ft
Non-operating Altitude
8200/30k
m / ft
Power Derating with Temperature
2.5
%/°C
50C to 70C
Power Derating with Altitude
2.0
C/301 m
C/1000 ft
Above 2250 m/7382 ft
Acoustic noise
55
dbA
Full load
Over Temperature Protection
125/110
°C
Shutdown / restart
Humidity
Operating
Storage
30
10
95
95
%
Relative humidity, non-condensing
Shock and Vibration acceleration
7.7
Grms
NEBS GR-63-CORE, Level 3, 20 -
2000Hz, min 30 minutes
Earthquake Rating
4
Zone
NEBS GR-63-CORE, all floors, Seismic
Zone 4 Designed and tested to meet
NEBS specifications.
EMC Compliance
Parameter
Criteria
Standard
Level
Test
DC input
Conducted emissions
EN55022, FCC Docket 20780 part 15,
subpart J
B 0.15
–
30MHz
Radiated emissions
6
EN55022
B 30
–
10000MHz
DC Input Immunity Fast transients
EN61000-4-4
B
5/50ns, 1kV
Enclosure immunity
Conducted RF fields
EN61000-4-6
A
130dBµV, 0.15-80MHz, 80%
AM
Radiated RF fields
EN61000-4-3
A
10V/m, 80-1000MHz, 80%
AM
ESD
EN61000-4-2
B
4kV contact, 8kV air
5
Designed to start at an ambient down to -40°C; meet spec after 30 min warm up period, may not meet operational limits below -10°C.
6