OSRAM PrevaLED Core Z3 User Manual
Page 6
6
PrevaLED
®
Core Z3 LED modules
|
Optical considerations
2.3 Refl ector mounting
The LED modules have a clearly defi ned optical contact
area (OCA), which provides a defi ned surface for attaching
the refl ector. In this confi guration, the mounting and mecha-
nical support of the refl ector must be ensured by the lumi-
naire body or by suitable structures for refl ector mounting.
The following has to be considered when mounting the re-
fl ector: Due to the creepage and clearance distances speci-
fi ed in the norm (IEC 61347-1/U935, among others), it is re-
commended to stay within the OCA values of the corres-
ponding category (see PrevaLED
®
datasheet).
Additionally, a bayonet base option is provided, with the
help of which the refl ector can be attached directly to the
PrevaLED
®
Core Z3.
Allowed compression: 20 N
Allowed tension: 20 N
Allowed torque: 1 Nm
2.4 Color temperature
The PrevaLED
®
Core Z3 series is currently available in 2 700
K, 3 000 K, 3 500 K and 4 000 K. The color coordinates
within the CIE 1931 color space are given below.
Within each available color temperature, the PrevaLED
®
Core Z3 series provides a maximum color variation of three
threshold value units (MacAdam steps). The following dia-
gram shows these threshold values within the CIE 1931
color space.
PrevaLED
®
Core Z3 3D fi les including the bayonet base for
design-in are available at:
www.osram.de/prevaled-core
.
2700 K
3000 K
3500 K
4000 K
Cx
0.4585 0.4345 0.4083 0.3828
Cy
0.4104 0.4033 0.3921 0.3803
Alux·Luxar GmbH & Co. KG
Schneiderstrasse 76
40764 Langenfeld, Germany
+49 2173 279 0
[email protected]
www.alux-luxar.de
Almeco S.p.A.
Via della Liberazione, 15
20098 San Giuliano, Milanese (Mi), Italy
+39 02 988963 1
[email protected]
www.almecogroup.com
Nata Lighting Co., Ltd.
380 Jinou Road, Gaoxin Zone
Jiangmen City, Guangdong, China
+86 750 377 0000
[email protected]
www.nata.cn
0.40
0.45
0.50
0.35
0.35
0.40
0.45
6000
4000
3000
2500
2000
x
y