OSRAM HALOTRONIC-PROFESSIONAL HTL User Manual
Page 9
![background image](/manuals/293050/9/background.png)
8
3.3 Operation on dc supplies The models indicated by the symbol = or 0 Hz in the technical data
can be operated on a dc supply and are therefore suitable for use in
emergency lighting to VDE 008. Lamps connected to HALOTRONIC
®
transformers emit the same luminous flux whether an ac or dc supply
is used. The permissible dc voltage range is 54 V to 244 V
)
.
3.4 Permissible temperature HALOTRONIC
®
transformers operate reliably within the temperature
range
range specified for each particular model (see technical data). Exces-
sive temperatures will cause electronic components to fail prematu-
rely and the transformer will not be able to achieve its specified life
expectancy.
Table
)
Below 207 V the safety protection in case of overload (e.g. additional lamp load)
is not provided anymore.
Model Separate converters
ta
tc
HT 70/230/2 L
60 °C
75 °C
HT 05/230/2 L
50 °C
80 °C
HT 50/230/2 L
55 °C
80 °C
HT 20/230/2 L
50 °C
80 °C
HT 20/230-240/2 LF
45 °C
80 °C
HTN 75/230-240/2 I
50 °C
85 °C
HTM 70/230-240
50 °C
80 °C
HTM 05/230-240
45 °C
85 °C
HTM 50/230-240
45 °C
80 °C
Built-in converters
HT 50/230-240/2 SB
70 °C
00 °C
HTN 75/230-240 S
50 °C
0
85 °C
t
a
: maximum permissible ambient temperature
t
c
: maximum permissible temperature at the control point of the transformer
~