beautypg.com

OSRAM HALOTRONIC-PROFESSIONAL HTL User Manual

Page 9

background image

8

3.3 Operation on dc supplies The models indicated by the symbol = or 0 Hz in the technical data

can be operated on a dc supply and are therefore suitable for use in
emergency lighting to VDE 008. Lamps connected to HALOTRONIC

®

transformers emit the same luminous flux whether an ac or dc supply
is used. The permissible dc voltage range is 54 V to 244 V

)

.

3.4 Permissible temperature HALOTRONIC

®

transformers operate reliably within the temperature

range

range specified for each particular model (see technical data). Exces-
sive temperatures will cause electronic components to fail prematu-
rely and the transformer will not be able to achieve its specified life
expectancy.

Table

)

Below 207 V the safety protection in case of overload (e.g. additional lamp load)

is not provided anymore.

Model Separate converters

ta

tc

HT 70/230/2 L

60 °C

75 °C

HT 05/230/2 L

50 °C

80 °C

HT 50/230/2 L

55 °C

80 °C

HT 20/230/2 L

50 °C

80 °C

HT 20/230-240/2 LF

45 °C

80 °C

HTN 75/230-240/2 I

50 °C

85 °C

HTM 70/230-240

50 °C

80 °C

HTM 05/230-240

45 °C

85 °C

HTM 50/230-240

45 °C

80 °C

Built-in converters
HT 50/230-240/2 SB

70 °C

00 °C

HTN 75/230-240 S

50 °C

0

85 °C

t

a

: maximum permissible ambient temperature

t

c

: maximum permissible temperature at the control point of the transformer

~