E4-LE Series 60 Hz
Reverse Osmosis Machine 2,200 to 13,200 gallons per day
Figure 1: E4-LE Series 60 Hz
When you mention reverse osmosis (RO), GE Water
& Process Technologies is the first name to come
to mind. Our E-series RO machines (Figure 1) are
designed for durable operation, high quality prod-
uct water production, easy installation and straight-
forward control.
General Properties
Typical Applications
Process ingredient water
Rinse water
Food ingredient water
Safe drinking water
Boiler feed water
Ion exchange pre-treatment
Standard Economy Features (ECN)
Low-energy design reduces electrical require-
ments and operating costs
RO Save.Zs*, 1 micron pre-filter
Automatic inlet shut-off valve
Permeate and Concentrate flow meters
Remote machine on/off capability
Thermal Motor Protection
Pre-filter, post-filter, primary, and final pressure
gauges
Flow control center including concentrate and
recycle valves
Deluxe (DLX) Features - in addition to ECN
features
Autoflush system
Low inlet pressure switch
Digital conductivity meter
Alarms: Low Inlet Pressure, Motor Starter
overload
Table 1: Operating Parameters
Operating Pressure
100-110 psig
(6.9-7.6 bar)
Maximum Recovery
75%
Nominal Rejection
95-98%
Operating Temperature
55-85
F
(13-30
C)
Minimum Inlet Pressure
30 psig (2 bar)
Design Temperature
77
F (25
C)