beautypg.com

GE P&W E-Series Reverse Osmosis - E4 LE 60 Hz User Manual

E4-le series 60 hz, General properties

background image

Fact Sheet

Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.

* Trademark of General Electric Company; may be registered in one or more countries.

©2013, General Electric Company. All rights reserved.

FS1144EN.doc Jul-13



E4-LE Series 60 Hz

Reverse Osmosis Machine 2,200 to 13,200 gallons per day

Figure 1: E4-LE Series 60 Hz

When you mention reverse osmosis (RO), GE Water
& Process Technologies is the first name to come
to mind. Our E-series RO machines (Figure 1) are
designed for durable operation, high quality prod-
uct water production, easy installation and straight-
forward control.

General Properties

Typical Applications

Process ingredient water

Rinse water

Food ingredient water

Safe drinking water

Boiler feed water

Ion exchange pre-treatment

Standard Economy Features (ECN)

Low-energy design reduces electrical require-
ments and operating costs

RO Save.Zs*, 1 micron pre-filter

Automatic inlet shut-off valve

Permeate and Concentrate flow meters

Remote machine on/off capability

Thermal Motor Protection

Pre-filter, post-filter, primary, and final pressure
gauges

Flow control center including concentrate and
recycle valves

Deluxe (DLX) Features - in addition to ECN
features

Autoflush system

Low inlet pressure switch

Digital conductivity meter

Alarms: Low Inlet Pressure, Motor Starter
overload

Table 1: Operating Parameters

Operating Pressure

100-110 psig
(6.9-7.6 bar)

Maximum Recovery

75%

Nominal Rejection

95-98%

Operating Temperature

55-85

F

(13-30

C)

Minimum Inlet Pressure

30 psig (2 bar)

Design Temperature

77

F (25

C)