Additional information – GE P&W Pleated Filters - Flotrex PN Pleated Filters User Manual
Page 2

Page 2
FS1082EN
Additional Information
• Flotrex PN filters may be autoclaved or in situ
steam sterilized (up to 257°F [125°C], 30-minute
cycles) for a maximum accumulated exposure
of 10 hours. Alternately, the filters may be sani-
tized with compatible chemical agents.
• GE certifies that the material contained in its
Flotrex PN pleated filters meet U.S. FDA
requirements for food contact under the appli-
cable regulations in 21 CFR. For further informa-
tion, contact GE technical services. Flotrex PN
filters meet the test criteria for USP class VI-
121°C Plastics.
• Aqueous extracts from Flotrex PN filters contain
less that 0.25 EU/ml. The filters typically exhibit
low levels of non-volatile residues.
• GE filter cartridges are designed and manufac-
tured for resistance to a wide range of chemical
solutions. Conditions will vary with each appli-
cation and users should carefully verify chemi-
cal compatibility. Please contact your GE
distributor for more information.
• Table 5 provides additional ordering information.
Table 4: Flow Performance in Clean Water
1
1
Data based on 10” length filter
Table 5: Ordering Information
Type
Nominal Micron
Rating
Nominal Cartridge
Length
End #1 Adapter
End #2 Adapter
Elastomer Material
FPN
92 = 0.2 µm
94 = 0.45 µm
01 = 1.0 µm
02 = 2.0 µm
03 = 3.0
µm
05 = 5.0 µm
10 = 10.0 µm
30 = 30,0 µm
1 = 10 inch (25 cm)
2 = 20 inch (51 cm)
3 = 30 inch (76 cm)
4 = 40 inch (102 cm)
A =
Open End Gasket
B =
120 O-Ring
C =
213 O-Ring
E =
222 O-Ring
F =
226 O-Ring
J =
020 O-Ring
Q =
222 O-Ring
Stainless Steel
Insert
2
Z = 226 O-Ring
Stainless Steel
Insert
2
A = Open End Gasket
B = 120 O-Ring
C = 213 O-Ring
G = Closed End Cap
H = Fin Adapter
B = Buna-N
E = EPDM
S = Silicone
T = Teflon
3
V = Viton
3
2
Q or Z Adapters normally require G or H adapters
3
Teflon and Viton on are registered trademarks of DuPont
Example: FPN921AAE