Standard Features

MK-3 E-Cell stacks allow for a simplified system
design, removing the need for concentrate re-
circulation as well as brine injection.

MK-3 E-Cell stack’s low energy design reduces
electrical requirements and operating costs.

Concentrate flow is in the opposite direction to
the Dilute flow, thus allowing systems to oper-
ate at higher hardness concentrations for long-
er periods of time.

Premium models available

Siemens S1200 PLC and HMI

Automatic Outlet Divert Valve

Full Owners Operation & Maintenance Manual,
Factory Acceptance Test results and Stack Per-
formance Test results

Direct Current Variable Freq. Drive (DC Drive)

Quality Assurance

Certification:

CE Marked

Facility:

ISO 9001:2000

Full Factory Acceptance Test (FAT) completed on
each system before shipment.






Instrumentation

Flow

Dilute (Product) Outlet

Concentrate Outlet

Electrode Outlet

Pressure

Dilute Inlet, Dilute Outlet

Concentrate Inlet, Concentrate Outlet

Electrode Outlet

Resistivity

Dilute (Product) Outlet

Feed Water Requirements

Total Exchangeable Anions < 25.0 ppm

(as CaCO

3

)

(TEA including CO

2

as calculated by E-Calc)

pH

5 – 9

Hardness

< 1.0 ppm

(as CaCO

3

)

Silica (Reactive)

< 1.0 ppm

SDI (15 min)

< 1

TOC

< 0.5 ppm

Total Chlorine

< 0.05 ppm

Fe, Mn, H

2

S

<0.01 ppm

Operating Parameters

Outlet (Dilute) Product Quality

> 16 MOhm-cm

Outlet Product Silica Guarantee Down to < 5ppb
Recovery:

Up to 95%

Temperature:

4.4 to 40

o

C (40 to 104

o

F)

Feed Pressure:

4.7 to 6.9 bar (70 to 100 psi)

Dilute Pressure Drop: 1.4 to 2.4 bar (20 to 35 psi)
Input Voltage:

400 VAC/3/50Hz