beautypg.com

Material of construction & ratings, Ecell3x standard systems – GE P&W Electrodeionization (EDI) - E-Cell-3X Standard Systems, 1 to 12 Stacks User Manual

Page 2

background image

Page 2

Fact Sheet

Material of Construction & Ratings

Welded Frame: ............................. Painted Carbon Steel
Dilute Piping: ...................................................... Sch. 80 PVC
Concentrate Piping: ......................................... Sch. 80 PVC

Flanges: ................................................................................ ANSI
Rectifier: ........................................................................ NEMA 4
Control Panel: ............................................................. NEMA 4
Control Panel Power: ................................................ 24VDC

ECell3X Standard Systems

Model

ECell3X-2

ECell3X-4

ECell3X-8

ECell3X-12

Number of Stacks

1 - 2

3 - 4

5 - 8

10 - 12

Type of stack

E-Cell-3X

E-Cell-3X

E-Cell-3X

E-Cell-3X

Flow Rates:

Product Flow Nominal

44 gpm

10 m

3

/h

88 gpm

20 m

3

/h

176 gpm

40 m

3

/h

264 gpm

59.9 m

3

/h

Range

15 – 56 gpm

3.4 – 12.7 m

3

/h

45 - 112 gpm

10.2 – 25.4 m

3

/h

75 - 224 gpm

17.0 – 50.9 m

3

/h

150 - 336 gpm

34.0 – 76.3 m

3

/h

Concentrate Outlet Flow
(Depends on Recovery &
Product Flow)

2

0.83 - 7.67 gpm

0.19 - 1.74 m

3

/h

2.50 - 15.34 gpm

0.57 - 3.48 m

3

/h

4.17 - 30.67 gpm

0.95 - 6.97 m

3

/h

8.34- 46.01 gpm

1.89 - 10.45 m

3

/h

Electrode Outlet Flow
(Nominal)

0.70 gpm

0.16 m

3

/h

1.40 gpm

0.32 m

3

/h

2.80 gpm

0.64 m

3

/h

4.20 gpm

0.95 m

3

/h

Dimensions:

Overall Dimensions
(Width x Length x Height)

42” x 50” x 84”

1.1m x 1.3m x 2.2m

46” x 75” x 84”

1.1m x 1.9m x 2.2m

64” x 103” x 90”

1.7m x 2.6m x 2.3m

64” x 130” x 90”

1.7m x 3.3m x 2.3m

Inlet Piping

2.0”

2.5”

4”

4”

Product Outlet Piping

1.5”

2.5”

3”

4”

Rinse Outlet Piping

1.5”

2.5”

3”

4”

Concentrate Outlet Piping

0.75”

1.0”

1.5”

1.5”

Electrode Outlet Piping

0.5”

0.5”

0.5”

0.5”

All piping sizes are provided for nominal flow rates at 90% recovery.

Shipping Weight (Approx.)

2050 lb /925 kg

3075 lb /1400 kg

5250 lb /2400 kg

6190 lb /3125 kg

Electrical:

Maximum Output @
400VDC

10.4 Amps

20.8 Amps

41.6 Amps

62.4 Amps

Connection Requirement

13 kVA

21 kVA

36 kVA

52 kVA


1. Performance, flow rate per stack, recovery and power consumption are all dependent on inlet feed water quality and temperature. An E-Calc

projection must be completed for proper system design & for any performance guarantee to be provided.

2. Concentrate outlet flow at 95% max recovery and minimal product flow of 15gpm/stack to 87% recovery and maximum product flow of

28gpm/stack.