Material of construction & ratings, Ecell3x standard systems – GE P&W Electrodeionization (EDI) - E-Cell-3X Standard Systems, 1 to 12 Stacks User Manual
Page 2
![background image](/manuals/286461/2/background.png)
Page 2
Fact Sheet
Material of Construction & Ratings
Welded Frame: ............................. Painted Carbon Steel
Dilute Piping: ...................................................... Sch. 80 PVC
Concentrate Piping: ......................................... Sch. 80 PVC
Flanges: ................................................................................ ANSI
Rectifier: ........................................................................ NEMA 4
Control Panel: ............................................................. NEMA 4
Control Panel Power: ................................................ 24VDC
ECell3X Standard Systems
Model
ECell3X-2
ECell3X-4
ECell3X-8
ECell3X-12
Number of Stacks
1 - 2
3 - 4
5 - 8
10 - 12
Type of stack
E-Cell-3X
E-Cell-3X
E-Cell-3X
E-Cell-3X
Flow Rates:
Product Flow Nominal
44 gpm
10 m
3
/h
88 gpm
20 m
3
/h
176 gpm
40 m
3
/h
264 gpm
59.9 m
3
/h
Range
15 – 56 gpm
3.4 – 12.7 m
3
/h
45 - 112 gpm
10.2 – 25.4 m
3
/h
75 - 224 gpm
17.0 – 50.9 m
3
/h
150 - 336 gpm
34.0 – 76.3 m
3
/h
Concentrate Outlet Flow
(Depends on Recovery &
Product Flow)
2
0.83 - 7.67 gpm
0.19 - 1.74 m
3
/h
2.50 - 15.34 gpm
0.57 - 3.48 m
3
/h
4.17 - 30.67 gpm
0.95 - 6.97 m
3
/h
8.34- 46.01 gpm
1.89 - 10.45 m
3
/h
Electrode Outlet Flow
(Nominal)
0.70 gpm
0.16 m
3
/h
1.40 gpm
0.32 m
3
/h
2.80 gpm
0.64 m
3
/h
4.20 gpm
0.95 m
3
/h
Dimensions:
Overall Dimensions
(Width x Length x Height)
42” x 50” x 84”
1.1m x 1.3m x 2.2m
46” x 75” x 84”
1.1m x 1.9m x 2.2m
64” x 103” x 90”
1.7m x 2.6m x 2.3m
64” x 130” x 90”
1.7m x 3.3m x 2.3m
Inlet Piping
2.0”
2.5”
4”
4”
Product Outlet Piping
1.5”
2.5”
3”
4”
Rinse Outlet Piping
1.5”
2.5”
3”
4”
Concentrate Outlet Piping
0.75”
1.0”
1.5”
1.5”
Electrode Outlet Piping
0.5”
0.5”
0.5”
0.5”
All piping sizes are provided for nominal flow rates at 90% recovery.
Shipping Weight (Approx.)
2050 lb /925 kg
3075 lb /1400 kg
5250 lb /2400 kg
6190 lb /3125 kg
Electrical:
Maximum Output @
400VDC
10.4 Amps
20.8 Amps
41.6 Amps
62.4 Amps
Connection Requirement
13 kVA
21 kVA
36 kVA
52 kVA
1. Performance, flow rate per stack, recovery and power consumption are all dependent on inlet feed water quality and temperature. An E-Calc
projection must be completed for proper system design & for any performance guarantee to be provided.
2. Concentrate outlet flow at 95% max recovery and minimal product flow of 15gpm/stack to 87% recovery and maximum product flow of
28gpm/stack.