GE P&W Electrodeionization (EDI) - E-Cell-3X Standard Systems, 1 to 12 Stacks User Manual

Ecell3x standard systems, E-cell*-3x, 1 to 12 stacks, Base system features

background image

Find a contact near you by visiting www.ge.com/water and clicking on “Contact Us” .

* Trademark of General Electric Company; may be registered in one or more countries.

©2011, General Electric Company. All rights reserved.

FSelE-Cell-3XStandard_1to12_EN.doc Sep-11

Fact Sheet

ECell3X Standard Systems

E-Cell*-3X, 1 to 12 Stacks

Base System Features

ECell3X Systems with 1 to 12 stacks for flow
range of 15 – 336gpm (3.4 - 76.3 m

3

/h)

Rectifier compatible with 400VAC & 50Hz or
460VAC & 60Hz

Individual stack current monitoring

Flow & pressure transmitters, ability to con-
nect to SCADA system

System Options

Allen Bradley Micrologix PLC with Ethernet
- Includes GE 6” Color QuickPanel View HMI

NEMA 4 Terminal Box - removal of PLC & HMI
and all wiring terminated at terminal box

Standard Instrumentation
- Burkert Paddlewheel flow sensors on Dilute,

Concentrate, and Electrode Outlet

- Burkert pressure transmitters on all

streams

- Burkert conductivity analyzer and sensor

on Dilute Outlet

Premium Instrumentation
- Rosemount vortex flow transmitters on Di-

lute and Concentrate Outlet

- Burkert Paddlewheel flow sensor on Elec-

trode Outlet

- Burkert pressure transmitters on all

streams

- Rosemount conductivity analyzer and sen-

sor on Dilute Outlet

Inlet Divert Valve
- Standard Instrumentation: Burkert

- Premium Instrumentation: Rosemount

ANSI to DIN conversion kits

Quality Assurance

Certification:.................................................................UL, CSA
Facility:............................................................. ISO 9001:2000
Full Factory Acceptance Test (FAT) completed on
each system before shipment.

Instrumentation

Flow .................................................. Dilute (Product) Outlet
Concentrate Outlet
Electrode Outlet
Pressure…… ............................... Dilute Inlet, Dilute Outlet
Concentrate Inlet, Concentrate Outlet
Electrode Outlet
Resistivity……………………………………Dilute Inlet (optional)
Dilute Outlet

Feed Water Requirements

Total Exchangeable Anions .......................... < 25.0 ppm

(as CaCO

3

)

(TEA) Including CO

2

as calculated by E-Calc

pH ........................................................................................ 4 – 11
Hardness ................................................ < 1.0 ppm

(as CaCO

3

)

Silica (Reactive) ...................................................... < 1.0 ppm
SDI (15 min) ........................................................................... < 1
TOC .............................................................................. < 0.5 ppm
Total Chlorine ...................................................... < 0.05 ppm
Fe, Mn, H

2

S ............................................................. <0.01 ppm

Operating Parameters

1

Outlet (Dilute) Product Quality ............ > 16 MOhm-cm
Outlet Product Silica Guarantee ...... Down to < 5ppb
Recovery: ............................................................... Up to 95%
Temperature: ......................... 40 to 104ºF (4.4 to 40ºC)
Feed Pressure: ................. 60 to 100 psi (4.1 to 6.9 bar)
Dilute Pressure Drop: ....... 20 to 40 psi (1.4 to 2.8 bar)
Input Voltage: .................. 460VAC 60Hz, 400VAC 50Hz