GE P&W Electrodeionization (EDI) - E-Cell-3X Standard Systems, 1 to 12 Stacks User Manual
Ecell3x standard systems, E-cell*-3x, 1 to 12 stacks, Base system features
Find a contact near you by visiting www.ge.com/water and clicking on “Contact Us” .
* Trademark of General Electric Company; may be registered in one or more countries.
©2011, General Electric Company. All rights reserved.
FSelE-Cell-3XStandard_1to12_EN.doc Sep-11
Fact Sheet
ECell3X Standard Systems
E-Cell*-3X, 1 to 12 Stacks
Base System Features
ECell3X Systems with 1 to 12 stacks for flow
range of 15 – 336gpm (3.4 - 76.3 m
3
/h)
Rectifier compatible with 400VAC & 50Hz or
460VAC & 60Hz
Individual stack current monitoring
Flow & pressure transmitters, ability to con-
nect to SCADA system
System Options
Allen Bradley Micrologix PLC with Ethernet
- Includes GE 6” Color QuickPanel View HMI
NEMA 4 Terminal Box - removal of PLC & HMI
and all wiring terminated at terminal box
Standard Instrumentation
- Burkert Paddlewheel flow sensors on Dilute,
Concentrate, and Electrode Outlet
- Burkert pressure transmitters on all
streams
- Burkert conductivity analyzer and sensor
on Dilute Outlet
Premium Instrumentation
- Rosemount vortex flow transmitters on Di-
lute and Concentrate Outlet
- Burkert Paddlewheel flow sensor on Elec-
trode Outlet
- Burkert pressure transmitters on all
streams
- Rosemount conductivity analyzer and sen-
sor on Dilute Outlet
Inlet Divert Valve
- Standard Instrumentation: Burkert
- Premium Instrumentation: Rosemount
ANSI to DIN conversion kits
Quality Assurance
Certification:.................................................................UL, CSA
Facility:............................................................. ISO 9001:2000
Full Factory Acceptance Test (FAT) completed on
each system before shipment.
Instrumentation
Flow .................................................. Dilute (Product) Outlet
Concentrate Outlet
Electrode Outlet
Pressure…… ............................... Dilute Inlet, Dilute Outlet
Concentrate Inlet, Concentrate Outlet
Electrode Outlet
Resistivity……………………………………Dilute Inlet (optional)
Dilute Outlet
Feed Water Requirements
Total Exchangeable Anions .......................... < 25.0 ppm
(as CaCO
3
)
(TEA) Including CO
2
as calculated by E-Calc
pH ........................................................................................ 4 – 11
Hardness ................................................ < 1.0 ppm
(as CaCO
3
)
Silica (Reactive) ...................................................... < 1.0 ppm
SDI (15 min) ........................................................................... < 1
TOC .............................................................................. < 0.5 ppm
Total Chlorine ...................................................... < 0.05 ppm
Fe, Mn, H
2
S ............................................................. <0.01 ppm
Operating Parameters
1
Outlet (Dilute) Product Quality ............ > 16 MOhm-cm
Outlet Product Silica Guarantee ...... Down to < 5ppb
Recovery: ............................................................... Up to 95%
Temperature: ......................... 40 to 104ºF (4.4 to 40ºC)
Feed Pressure: ................. 60 to 100 psi (4.1 to 6.9 bar)
Dilute Pressure Drop: ....... 20 to 40 psi (1.4 to 2.8 bar)
Input Voltage: .................. 460VAC 60Hz, 400VAC 50Hz