Fact Sheet

Duratherm* HWS Series

Hot Water Sanitization Pure Water Elements

Description and Use

The Duratherm* HWS Series includes RO, NF and

UF membrane elements. This Series is specifically

designed to maximize the benefits of hot water

sanitization for industries relying on chemical free

sanitization for product quality and/or industry

compliance standard.
Separation system sanitization protocol is per-

formed via periodic exposure to temperature as

high as 195°F (90°C) at minimum feed pressure to

kill microorganisms by denaturation and coagula-

tion of the proteins chains.
The Duratherm HWS RO and HWS NF are suitable

for separation systems purifying water at temper-

ature up to 122°F (50°C) in low crossflow environ-

ment and no suspended solids.
This Series includes a variety of size 8”, 4” and 2.5”

diameters. All element constructions include

Durasan* Cage outer wrap, Polysulfone ATD and

central tube.

Features and Benefits

• Prevent bio-fouling development

• No disposal costs

• 100% wet testing Quality Assurance

• Durable construction

• Sanitization on the permeate side

Markets

• Food / Beverage

• BioPharm

• Electronics

• Chemical

Table 1: Element Specification

Membrane

A-Series, Thin-film membrane (TFM*)

a,b

D-Series, Thin-film membrane (TFM*)

c

P-Series, Polyethersulfone

d

a=HWS RO-HR, b=HWS RO, c=HWS NF, d=HWS UF

Model

Maximum

Crossflow

gpm (m3/h)

Average

permeate flow

gpd (m3/day)

Average salt

rejection

/ MWCO

Duratherm HWS RO2540HR

1,4

4 (0.9)

620 (2.3)

99.5%

Duratherm HWS RO4040HR

1,4

20 (4.5)

2,300 (8.7)

99.5%

Duratherm HWS RO8040HR

1,4

65 (14.8)

9,900 (37.5)

99.5%

Duratherm HWS RO2540

2,4

4 (0.9)

760 (2.9)

99.0%

Duratherm HWS RO4040

2,4

20 (4.5)

2,200 (8.3)

99.0%

Duratherm HWS RO8040

2,4

65 (14.8)

9,200 (34.8)

99.0%

Duratherm HWS RO8040, WET

65 (14.8)

9,200 (34.8)

99.0%

Duratherm HWS SG8040

2

60 (13.62)

8,600 (32.6)

98.5%

Duratherm HWS NF4040

3,4

20 (4.5)

2,100 (7.9)

98.6%

Duratherm HWS NF8040

3,4

65 (14.8)

8,500 (32.2)

98.6%

Duratherm HWS UF8040

65 (14.8)

--

10,000 Da

1

Testing conditions: 2,000ppm NaCl solution at 225psig (1,550kPa) operating

pressure, 77°F, pH7.5 and 15% recovery before any hot water sanitization.

2

Testing conditions: 500ppm NaCl solution at 115psig (790kPa) operating

pressure, 77°F, pH7.5 and 15% recovery before any hot water sanitization.

3

Testing conditions: 2,000ppm MgSO4 solution at 110psig (760kPa) operating

pressure, 77°F, pH7.5 and 15% recovery before any hot water sanitization

4

Average salt rejection after 24 hours operation. Individual flow rate may vary

+25%/-15%. Final permeate flow rate is subject to variations in the heat treat-
ments. In most cases, the permeate flow rate after heat treatments will stabi-
lize at 30-50 percent below the nominal flowrate before heat treatment. For a
conservative design, consider a permeate flow reduction of 50%.