beautypg.com

Membrane elements and housings, Cartridge filtration, Ge pro-ap-60hz models – GE P&W PRO AP Series 60 Hz User Manual

Page 2

background image

Fact Sheet

Page 2

Membrane Elements and Housings

Membrane model

AG8040F

Style

Spiral-wound elements

Membrane manufacturer

GE

Membrane type

TFC (Polyamide)

Average membrane flux

1

28 lmh (16.4 gfd)

Membrane rejection

99.0-99.6%

Housing manufacturer

Wave Cyber or Equal

Housing material

FRP

1

Flux can be reduced to 25.5 lmh (15 gfd) by using 400sqft

elements. Rated flow can be further reduced by up to 20%.

Cartridge Filtration

Housing model

7 Rounds, 102cm (40“)

Housing material

316 SS

Cartridge filter

1-micron nominal, ROsave.Z*s




GE PRO-AP-60hz Models

MODEL

PRO-11-AP-60

PRO-23-AP-60

PRO-34-AP-60

PRO-45-AP-60

PRO-68-AP-60

PRO-102-AP-60

Permeate rate:

2

Concentrate Rate:
Feed Rate:

11.4 m

3

/hr

3.8 m

3

/hr

15.1 m

3

/hr

22.7 m

3

/hr

7.5 m

3

/hr

30.2 m

3

/hr

34.1 m

3

/hr

11.4 m

3

/hr

45.4 m

3

/hr

45.4 m

3

/hr

14.9 m

3

/hr

60.4 m

3

/hr

68.1 m

3

/hr

22.7 m

3

/hr

90.8 m

3

/hr

102.2 m

3

/hr

34.1 m

3

/hr

136.3 m

3

/hr

Pumps and Motors

Manufacturer:
Model:
Quantity:
Motor HP:
Design Flow Rate:
Design boost pressure:

Xylem

15SV07N1106T

1

11 kW

18.2 m

3

/hr

12.4 bar

Xylem

33SV4N1856T

1

18.5 kW

32.4 m

3

/hr

12 bar

Xylem

46SV4N3006T

1

30 kw

45.4 m

3

/hr

12.6 bar

Xylem

66SV4/2AN3706T

1

37 kw

64.9 m

3

/hr

12 bar

Xylem

46SV4N3006T

2

2 x 30 kW

90.8 m

3

/hr

12.6 bar

Xylem

66SV4N3706T

2

2 x 37 kW
136.3 m

3

/hr

13.6 bar

Membrane Elements and Housings

Membranes quantity:
Memb. housing style:
Banking Arrangement:

12

4 element long, 4 port

1

1

1

24

4 element long, 4 port

3

2

1

36

6 element long, 4 port

3

2

1

48

4 element long, 4 port

6

4

2

72

6 element long, 4 port

6

4

2

108

6 element long, 4 port

9

6

3

Cartridge Filtration

Cartridge Filter:
Filter Length:
Filter Quantity:

RO.Zs01-40

102 cm (40”)

7 per housing

7/change out

RO.Zs01-40

102 cm (40”)

7 per housing

7/change out

RO.Zs01-40

102 cm (40”)

7 per housing

14/change out

RO.Zs01-40

102 cm (40”)

7 per housing

14/change out

RO.Zs01-40

102 cm (40”)

7 per housing

21/change out

RO.Zs01-40

102 cm (40”)

7 per housing

28/change out

Installation and Utility Requirements

Inlet:
Permeate:
Concentrate:
Inlet Water Pressure:
Air Pressure:
Drain to be Sized for:
Power:
Control Circuit:

ANSI 2" flange
ANSI 2" flange

ANSI 1.5" flange 2.1 2

bar min.

6.9 bar, oil-free

15.1 m

3

/hr

380-480 VAC, 3-ph, 60Hz
110-230 VAC, 1-ph, 60Hz

ANSI 3" flange
ANSI 3" flange

ANSI 1.5" flange

2 bar min.

6.9 bar, oil-free

30.2 m

3

/hr

380-480 VAC, 3-ph, 60Hz
110-230 VAC, 1-ph, 60Hz

ANSI 3" flange
ANSI 3" flange

ANSI 1.5" flange

2 bar min.

6.2 bar, oil-free

45.4 m

3

/hr

380-480 VAC, 3-ph, 60Hz
110-230 VAC, 1-ph, 60Hz

ANSI 4" flange
ANSI 3" flange
ANSI 2" flange

2 bar min.

6.2 bar, oil-free

60.4 m

3

/hr

380-480 VAC, 3-ph, 60Hz
110-230 VAC, 1-ph, 60Hz

ANSI 4" flange
ANSI 4" flange
ANSI 2" flange

2 bar min.

6.9 bar, oil-free

90.8.0 m

3

/hr

380-480 VAC, 3-ph, 60Hz
110-230 VAC, 1-ph, 60Hz

ANSI 6" flange
ANSI 4" flange
ANSI 3" flange

2 bar min.

6.9 bar, oil-free

136.3 m

3

/hr

380-480 VAC, 3-ph, 60Hz
110-230 VAC, 1-ph, 60Hz

Skid

Approx.Height:
Approx. Width:
Approx.Depth:
Approx. Shipping
Weight :

2000 mm

800 mm

4900 mm

1543 kg

2200 mm

900 mm

5050 mm

2132 kg

2240 mm

950 mm

6850 mm

2722 kg

2240 mm
1250 mm
5200 mm

3085 kg

2420 mm
1400 mm
6950 mm

4490 kg

2475 mm
1850 mm
7080 mm

6124 kg

2