beautypg.com

GE P&W PRO AP Series 60 Hz User Manual

Pro ap series 60 hz, Basic features, Materials of construction

background image

Find a contact near you by visiting www.ge.com/water and clicking on “Contact Us”.

* Trademark of General Electric Company; may be registered in one or more countries.

©2013, General Electric Company. All rights reserved.

AP-FSpwPRO_AP_Series_60Hz_EN.doc Apr-13

Fact Sheet

PRO AP Series 60 Hz

Reverse Osmosis Machines from 11 to 102 m

3

/hr

Basic Features

1000 mg/L feed TDS and 20C water tempera-
ture design

GE Intelligent Platforms' VersaMax Micro PLC
with 6-inch QuickPanel monochrome
touchscreen.

Xylem SV high pressure pump

Communication: RS232/DH485

4-20 mA instrument display on instrument
center

Materials of Construction

High-pressure piping

316 SS, Sch. 10

Low-pressure piping

PVC, Sch. 80

Frame

Painted blue carbon steel

Enclosure

IP54 (painted carbon steel)

Instrumentation

Flow Meters

Permeate, concentrate

Conductivity

Permeate

Pressure

Pre-filter, post-filter, primary,

final, permeate, concentrate,

pump discharge

Pressure Switch

Feed, permeate, concentrate

pH (Optional)

Feed

ORP (Optional)

Feed

Instrument Center

Signet 8900

Options Available

Premium controls and instrument package

pH and ORP sensors added to Basic package

Skid mounted motor starter (Wye-Delta) added
to basic package

High Rejection Membrane Elements

PRO Clean-in-Place units

Allen Bradley PLC and HMI packages

Grundfos CRN high pressure pump(s)

Documentation Included

Operation and maintenance manual

Drawings: piping and instrumentation, electrical
and general dimension

Operating Parameters

Design Recovery

1

75%

Design temp.

20ºC

Operating range

2 to 30ºC

Nominal rejection

97-99%

Design inlet pressure

2-4 bar

1

Recovery Rate can vary +/- 5%