beautypg.com

Membrane elements and housings continued, Cartridge filtration, Pro na models – GE P&W PRO NA Series 60 Hz User Manual

Page 2: Average membrane flux -17 gfd, Pumps and motors, Membrane elements and housings, Installation and utility requirements, Skid

background image

AM-FSpwPRO_NA_Series_60Hz_EN.doc

Page 2

Membrane Elements and Housings
continued

Average membrane flux ............................................. 16-17 gfd

1

Membrane rejection ............................................... 99.0 to 99.5%
Manufacturer......................................................................................GE
Housing material ............................ 316 Stainless Steel or FRP
Housing Pressure Rating .................................................. 450 psi

1

Flux can be reduced by using 400-sqft membranes.

Cartridge Filtration

Housing model ......................................... GE HX-0740-80-V316
Housing material .......................................... 316 Stainless Steel
Cartridge filter ....................... 1-micron nominal, ROsave.Z*s



PRO NA Models

MODEL

PRO-50-NA

PRO-100-NA

PRO-150-NA

PRO-200-NA

PRO-300-NA

PRO-450-NA

Permeate Rate

2

:

Concentrate Rate:
Concentrate Recycle:
Feed Rate:

50 gpm (11 m

3

/hr)

13 gpm (3 m

3

/hr)

10 gpm (2.3 m3/hr)

63 gpm (14 m

3

/hr)

100 gpm (23 m

3

/hr)

25 gpm (6 m

3

/hr)

10 gpm (2.3 m3/hr)

125 gpm (28.5 m

3

/hr)

150 gpm(34 m

3

/hr)

38 gpm (8.5 m

3

/hr)

NA

188 gpm (43 m

3

/hr)

200 gpm (45 m

3

/hr)

50 gpm (11 m

3

/hr)

15 gpm (3.4 m3/hr)

250 gpm (57 m

3

/hr)

300 gpm (68 m

3

/hr)

75 gpm (17 m

3

/hr)

NA

375 gpm (85 m

3

/hr)

450 gpm (100 m

3

/hr)

113 gpm (26 m

3

/hr)

NA

563 gpm (128 m

3

/hr)

Pumps and Motors

Model:
Manufacturer:
Quantity:
Motor Power and type:
Installed Power:
Design Flow Rate:
Design boost pressure:

SS8516

GE/Tonkaflo

1

25HP (18.6 KW) TEFC

18.6 KW

73 gpm (17 m

3

/hr)

330 psig (23 Bar)

SS12512

GE/Tonkaflo

1

40 Hp (30 KW) TEFC

30 KW

135 gpm (31 m

3

/hr

275 psig (19 Bar)

SS24009

GE/Tonkaflo

1

60 Hp (45 KW) TEFC

45 KW

188 gpm (43 m

3

/hr)

280 psig (19.3 Bar)

AS40407

GE/Tonkaflo

1

60 Hp (45 KW) TEFC

45 KW

265 gpm (60 m

3

/hr)

240 psig (16.5 Bar)

AS40409

GE/Tonkaflo

1

75 Hp (56 KW) TEFC

56 KW

375 gpm (85 m

3

/hr)

260 psig (18 Bar)

AS40409

GE/Tonkaflo

2

75 Hp (56 KW) TEFC

112 KW

563 gpm (128 m

3

/hr)

300 psig (20.7 Bar)

Membrane Elements and Housings

Membranes Quantity:
Memb. Housing Style:

Banking Arrangement:

12

4 element long,

4 port

1

1

1

24

4 element long,

4 port

3

2

1

36

6 element long,

4 port

3

2

1

48

4 element long,

4 port

6

4

2

72

6 element long,

4 port

6

4

2

108

6 element long,

4 port

9

6

3

Cartridge Filtration

Housing Model:
Housing Quantity:
Cartridge Filter Model:
Cartridge Filter Length:
Cartridge Filter Qty:

HX-0740-3.0-V-316

1

RO.Zs01-40XK

40-inch (120 cm)

7 per housing,

7/change out

HX-0740-3.0-V-316

1

RO.Zs01-40XK

40-inch (102 cm)

7 per housing,

7/change out

HX-0740-3.0-V-316

2

RO.Zs01-40XK

40-inch (102 cm)

7 per housing,

14/change out

HX-0740-3.0-V-316

2

RO.Zs01-40XK

40-inch (102 cm)

7 per housing,

14/change out

HX-0740-3.0-V-316

3

RO.Zs01-40XK

40-inch (102 cm)

7 per housing,

21/change out

HX-0740-3.0-V-316

4

RO.Zs01-40XK

40-inch (102 cm)

7 per housing,

28/change out

Installation and Utility Requirements

Inlet:
Permeate:
Concentrate:
Inlet Water Pressure:
Air Pressure:
Drain to be Sized for:
Power:
Control Circuit

2.0” flange
1.5” flange
1.0” flange
30-60 psig

80 psi, oil-free

67 gpm (15 m

3

/hr)

460-480 VAC, 3-phase,

60Hz

120 VAC, 1-phase, 60Hz

3.0” flange
3.0” flange
1.5” flange
30-60 psig

80 psi, oil-free

133 gpm (30 m

3

/hr)

460-480 VAC, 3-phase,

60Hz

120 VAC, 1-phase, 60Hz

3.0” flange
3.0” flange
1.5” flange
30-60 psig

80 psi, oil-free

200 gpm (45 m

3

/hr)

460-480 VAC, 3-phase,

60Hz

120 VAC, 1-phase, 60Hz

4.0” flange
3.0” flange
2.0” flange
30-60 psig

80 psi, oil-free

267 gpm (61 m

3

/hr)

460-480 VAC, 3-phase,

60Hz

120 VAC, 1-phase, 60Hz

4.0” flange
4.0” flange
2.0” flange
30-60 psig

80 psi, oil-free

400 gpm (91 m

3

/hr)

460-480 VAC, 3-phase,

60Hz

120 VAC, 1-phase, 60Hz

6.0” flange
6.0” flange
3.0” flange
30-60 psig

7 bar, oil-free

600 gpm (136 m

3

/hr)

460-480 VAC, 3-phase,

60Hz

120 VAC, 1-phase, 60Hz

Skid

Height:
Width:
Depth:
Skid Shipping Weight
Estimate Without
Membranes:
Membranes Shipping
Weight Estimate:
Operating Weight
Estimate:

79” (200 cm)
46” (117 cm)

194” (493 cm)


3454 lb (1567kg)

420 lb (191 kg)

4300 lb (1951 kg)

79” (200 cm)

47” (119cm)

194” (493 cm)


4408 lb (2000 kg)

840 lb (381 kg)

5650 lb (2563 kg)

79” (200 cm)

47” (119cm)

274” (696 cm)


5712 lb (2591 kg)

1260 lb (572 kg)

7550 lb (3425 kg)

79” (200 cm)
80” (203 cm)

194” (493 cm)


6966 lb (3160 kg)

1680 lb (762 kg

9400 lb (4264 kg)

79” (200 cm)
80” (203 cm)

274” (696 cm)


8624 lb (3912 kg)

2520 lb (1143 kg)

12000 lb (5443 kg)

102” (259 cm)

80” (203 cm)

276” (701cm)


13736 lb (6231 kg)

3780 lb (1715 kg)

19600 lb (8890 kg)

2