GE P&W IPER Integrated Pump and Energy Recovery User Manual
Iper, Integrated pump and energy recovery for 1,000 m, D seapro
Fact Sheet
Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.
* Trademark of General Electric Company; may be registered in one or more countries.
©2013, General Electric Company. All rights reserved.
FSppIPER_EN.doc Jun-13
IPER*
Integrated Pump and Energy Recovery for 1,000 m
3
/d SeaPRO*
Figure 1: GE’s IPER, inset picture shows hydraulic device
Features
Highly Efficient Positive Displacement (PD)
Pump technology for desalination applications
Solid-state control system for robust, consistent
operation of plant capable of integrating into
existing PLC systems
Smooth, Consistent Flow and Pressure outputs
Basic Specifications
Capacity ............................................. 2,222 to 2,857 m
3
/day
(587k to 755k gpd)
SWRO Recovery .................................................. 35% to 45%
SWRO Permeate ....................... 1,000 m
3
/day (264k gpd)
Discharge Pressure (to membranes) ........ 10 to 80 bar
Supply Pressure (to IPER) ................................... 1 to 10 bar
Electric Motor .......................................... 200 h.p. 1800 rpm
Operating Temperature Range ....... 15-29ºC (59-85ºF)
Materials of Construction
High-pressure piping ...... 2205 Stainless Steel, Sch. 10
Low-pressure piping ......................................... PVC, Sch. 80
Frame ........................................... Painted blue carbon steel
Control Enclosure ............................................................ IP 548
Water Displacement Unit
Three Water Cylinders with dual-acting pistons
Feed Water Valves and Energy Recovery Valves
on all cylinders
Hydraulic Power Unit
Highly Efficient Hydraulic pumps provide the
energy to power the Water Displacement Unit
Hydraulic Cylinders transfer the energy from the
Hydraulic Pumps to the dual-acting pistons
Electronic Control Unit
Sophisticated Solid State control system syn-
chronizes positioning of the dual-acting pistons
and ensures all valves open and close at near
zero flow
Control System is designed to provide long last-
ing, stable control delivering a steady flow and
pressure output from the Water Displacement
Unit
Utilities Required
Motor Voltage (3 phase) .......................... 380 or 460 VAC
Control Voltage (1 phase) ....................... 120 or 220 VAC
Frequency ................................................................ 50 or 60 Hz
Foot Print .............................................................. 2.6 m X 6.0 m
Compressed Air ........................... 10 bar oil-free shop air
Connection Sizes
Feed Water In ....................................... 4.0 inch Cut Groove
High Pressure Out .............................. 4.0 inch Roll Groove
Concentrate In ..................................... 3.0 inch Roll Groove