beautypg.com

GE P&W IPER Integrated Pump and Energy Recovery User Manual

Iper, Integrated pump and energy recovery for 1,000 m, D seapro

background image

Fact Sheet

Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”.

* Trademark of General Electric Company; may be registered in one or more countries.

©2013, General Electric Company. All rights reserved.

FSppIPER_EN.doc Jun-13



IPER*

Integrated Pump and Energy Recovery for 1,000 m

3

/d SeaPRO*

Figure 1: GE’s IPER, inset picture shows hydraulic device

Features

Highly Efficient Positive Displacement (PD)
Pump technology for desalination applications

Solid-state control system for robust, consistent
operation of plant capable of integrating into
existing PLC systems

Smooth, Consistent Flow and Pressure outputs

Basic Specifications

Capacity ............................................. 2,222 to 2,857 m

3

/day

(587k to 755k gpd)

SWRO Recovery .................................................. 35% to 45%
SWRO Permeate ....................... 1,000 m

3

/day (264k gpd)

Discharge Pressure (to membranes) ........ 10 to 80 bar
Supply Pressure (to IPER) ................................... 1 to 10 bar
Electric Motor .......................................... 200 h.p. 1800 rpm
Operating Temperature Range ....... 15-29ºC (59-85ºF)

Materials of Construction

High-pressure piping ...... 2205 Stainless Steel, Sch. 10
Low-pressure piping ......................................... PVC, Sch. 80
Frame ........................................... Painted blue carbon steel
Control Enclosure ............................................................ IP 548

Water Displacement Unit

Three Water Cylinders with dual-acting pistons

Feed Water Valves and Energy Recovery Valves
on all cylinders

Hydraulic Power Unit

Highly Efficient Hydraulic pumps provide the
energy to power the Water Displacement Unit

Hydraulic Cylinders transfer the energy from the
Hydraulic Pumps to the dual-acting pistons

Electronic Control Unit

Sophisticated Solid State control system syn-
chronizes positioning of the dual-acting pistons
and ensures all valves open and close at near
zero flow

Control System is designed to provide long last-
ing, stable control delivering a steady flow and
pressure output from the Water Displacement
Unit

Utilities Required

Motor Voltage (3 phase) .......................... 380 or 460 VAC
Control Voltage (1 phase) ....................... 120 or 220 VAC
Frequency ................................................................ 50 or 60 Hz
Foot Print .............................................................. 2.6 m X 6.0 m
Compressed Air ........................... 10 bar oil-free shop air

Connection Sizes

Feed Water In ....................................... 4.0 inch Cut Groove
High Pressure Out .............................. 4.0 inch Roll Groove
Concentrate In ..................................... 3.0 inch Roll Groove
Concentrate Out .................................. 3.0 inch Cut Groove