FS1077EN

Quality Assurance & Traceability

Memtrex MP filters are manufactured under a
quality management system that has been certi-
fied to meet ISO 9001 standards. Each filter is
assigned a lot code to ensure traceability of the
data and materials used in the manufacturing
process.

Integrity Testing

For assured quality and performance, the subas-
semblies used to construct the Memtrex MP filters
are individually integrity tested.

Pore Size Rating

Specification

0.03 µm

≤ 45 cc/min at 50 psig (3.4 bar)

0.1 µm

≤ 45 cc/min at 50 psig (3.4 bar)

0.2 µm

≤ 19 cc/min at 30 psig (2.1 bar)

0.45 µm

≤ 16 cc/min at 20 psig (1.4 bar)

0.65 µm

≤ 12 cc/min at 13 psig (0.9 bar)

Air diffusion per 10” module after saturation with clean water

Filtration Efficiency and Microbial
Retention

Memtrex MP filters are absolute rated. Repre-
sentative filters meeting integrity test specifica-
tions have demonstrated ≥ 99.9% initial particle
retention efficiency at the rated pore size based
on ASTM F661 test methodology.
Memtrex MP filters have good microbial retention
for reliable bioburden control. Representative
filters meeting integrity test specifications have
demonstrated the following microbial retention
characteristics based on ASTM F838 test method-
ology.

Pore Size
Rating

Test Organism

Log Reduction

Value (LRV)

0.2 µm

Brevundimonas diminuta

≥7

0.45 µm

Searratia marcescens

≥7

0.65 µm

Pediococcus damnosus

≥7

Sanitization

Memtrex MP filters may be autoclaved or in situ
steam sterilized. Filters which are steam sterilized
must have Z or Q adaptors.

Medium

Maximum
Temperature

Maximum Cumulative
Exposure

Steam

125°C (257°F)

10 hours

Alternatively, the filters may be sanitized with com-
patible chemical agents.

Operational Limits

Description

Operational Limits

Max. Forward Differential
Pressure

60 psi (4.1 bar) at 70ºF (21ºC)

Max. Reverse Differential
Pressure

30 psi (2.1 bar) at 70ºF (21ºC)

Max. Operating Temperature 180ºF (82ºC) at 10 psid (0.7 bar)

in water

Flow Performance in Clean Water

1

Data based on 10” length filter


0.03 µm