beautypg.com

Peerless-AV CMJ470W - Installation User Manual

Warning

background image

ISSUED: 08-12-04 SHEET #: 128-9152-1

Visit the Peerless Web Site at www.peerlessindustries.com

For customer service call 1-800-729-0307 or 708-865-8870.

1

of

2

For Wood Joist Finished Ceiling, Exposed
Wood Joists, or Wood Beam Ceiling.
(See
step 3 for concrete ceilings). Drill four 5/32" (4
mm) dia. holes to a minimum depth of 2.5" (64
mm). Attach with four #14 x 2.5" (6 mm x 65
mm) wood screws as shown using 3/8" (10
mm) socket wrench. Tighten wood screws so
ceiling plate is firmly attached.

flush mount tube
(included with Jumbo
Mount Bracket)

ceiling
plate

From the top thread the Flush Mount Tube
(included with your Jumbo Mount Bracket)
through the threaded fitting in the ceiling plate.

IMPORTANT: If you will install an extension
column DO NOT INSTALL THE FLUSH
MOUNT TUBE. Begin with step 2.

IMPORTANT!

Read entire instruction sheet before beginning installation and assembly.

Installation and Assembly - Ceiling Plate for

Jumbo Mounts

Models: CMJ 470W, CMJ 480W,
CMJ 490W

This Ceiling Plate is intended for use only to support
Jumbo Mount TV Brackets or other products as
specified by Peerless Industries, Inc. Combine only
as specified (see specifications on page 2). Fasten-
ers provided are for attachment to wood structural
members (joists or beam). Order additional fastener
kit ACC 204 if attaching to a solid concrete ceiling.

CEILING CONSTRUCTION

ADDITIONAL HARDWARE REQUIRED

Wood Joist, Wood Beam

none

Concrete

Concrete Anchor Kit - order accessory kit ACC 204.

Other or unsure?

Call Peerless Customer Service.

IMPORTANT!

Certain ceilings require additional mounting hardware...

MAXIMUM LOAD CAPACITY:

300 lb (137 kg)

end
cap

R

This product is intended for use with UL
Listed products and must be installed by a
qualified professional installer.

• Installer must verify that the ceiling will safely support

four times the combined weight of all attached equip-
ment and hardware.

WARNING

• Tighten wood screws so that ceiling plate is firmly

attached, but do not overtighten. Overtightening can
damage the screws, greatly reducing their holding
power.

• Never tighten in excess of 80 in • lb (9 N.M.).

• Make sure that mounting screws are anchored into the

center of the studs. The use of an "edge to edge" stud
finder is highly recommended.

WARNING

PARTS LIST

PART #

QTY.

DESCRIPTION

128-2039

1

ceiling plate (CMJ 470W only)

128-2086

1

ceiling plate (CMJ 480W only)

128-2087

1

ceiling plate (CMJ 490W only)

5S1-015-C03

4

#14 x 2.5" (6 mm x 65 mm) wood screw

2PT-22CA01F

2

end cap (white models only)

520-9250

1

M5 x .8 x 10 mm phillips screw (for use
with extension column if applicable)