beautypg.com

B&B Electronics ESP904 - Manual User Manual

Page 82

background image

RS-422 Connections

72

Appendix B

Manual Documentation Number: ESP904-4513m

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com

B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

Figure 64. RS-422 Connections with Flow Control

In the RS-422 mode, TXD lines are outputs and RXD lines are inputs.
Connect the ESP904 TXDB(+) line to the RXDB(+) line of the serial device,
and the ESP904 TXDA(-) to the RXDA(-) of the serial device.

If Flow Control is set for RTS/CTS, connect the ESP904 RTSB(+) to
CTSB(+) of the serial device and the ESP904 RTSA(-) line to the CTSA(-)
of the serial device. Connect from the ESP904 CTSB(+) line to the RTSB(+)
of the serial device and from the ESP904 CTSA(-) line to the RTSB(+) line
of the serial device.

If connecting to Receive Only RS-422 devices, connect from the ESP904
TXDB(+) and TXDA(-) lines to the receive pairs on all serial devices.

Ground is signal ground and provides a common mode reference for the RS-
422 Receiver and Transmitters.

N

N

o

o

t

t

e

e

:

:

The RS-422 mode can be used for full duplex 4-wire RS-485 operation provided
that the ESP904 is acting as a sole master connecting to all the slave devices,
and all slave devices share the Receive signal lines to the master. Set Flow
Control for none, and omit connections to RTS/CTS line pairs.

ESP904 pin-out

in RS-422 mode

RS-422

Device

RS-422 Signal Names

DB-9

Pin#

Connections

Signal

Receive A (-)

RXDA(-)

1

TDA(-)

Receive B (+)

RXDB(+)

2

TDB(+)

Transmit B (+)

TXDB(+)

3

RDB(+)

Transmit A (-)

TXDA(-)

4

RDA(-)

Ground

GND

5

GND

Clear to Send A (-)

CTSA(-)

6

RTSA(-)

Clear to Send B (+)

CTSB(+)

7

RTSB(+)

Ready to Send B (+)

RTSB(+)

8

CTSB(+)

Ready to Send A (-)

RTSA(-)

9

CTSA(-)