B&B Electronics ESP904 - Manual User Manual
Page 74

ESP904 Technical Data
64
Chapter 12
Manual Documentation Number: ESP904-4513m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Data Bits:
7 or 8
Stop Bits:
1, 1.5 or 2
Memory
Serial Memory:
8K bytes per port
Network
Communications
LAN:
10/100 Mbps Auto-detecting 10 BaseT or 100
BaseTX
Protocols
TCP, IP, ARP, DHCP, Telnet, HTTP, UDP,
ICMP
Configuration
Options
Console Mode:
Using RS-232 with VT100 emulation
Telnet Mode:
Using HyperTerminal with VT100 emulation
ESP Manager: Using Windows 98/ME/2000/2003/XP/Vista/NT
software
Web Server:
Using a standard web browser such as Internet
Explorer
Default Server
Settings
Server Name
ESP904
Serial Number:
XXXXXXXXXX
Password:
Blank
DHCP:
Disable
IP Address:
192.168.0.1
Net Mask:
255.255.255.0
Gateway:
192.168.0.254
MAC Address:
Fixed – see bottom label
Port 1
Console Mode
Ports 2, 3, 4
RS-232
Baud Rate:
9600
Data/Parity/Stop:
8-N-1
Flow Control:
None
TCP/UDP Ports:
TCP Port 1 – 4000
TCP Port 2 – 4001
TCP Port 3 – 4002
TCP Port 4 – 4003
Connection Mode:
Server
Remote IP Address:
255.255.255.255
Optional
Accessories
232NM9 Null Modem Crossover Cable for DTE to DTE connection
DRAD35 DIN Rail mounting clips for 35mm DIN Rail
ERS35 one-meter length of steel 35mm DIN Rail