Using ESP Manager

20

Chapter 4

Manual Documentation Number: ESP904-4513m

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com

B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

Searching Server

- Searches for

Serial Servers

on the network and

brings back configuration information that will be displayed in the

Server Properties

window.

Uninstall Virtual COM

- Allows virtual COM ports to be uninstalled

from the

ESP Manager

window.

Monitor Port Status

- Brings up a screen that displays the following

information associated with the selected serial port.

Figure 18. The Port Status Window

o Serial TX: Displays the number of bytes of data sent to the

serial device

since the IP connection was established.

o Serial RX: Displays the number of bytes of data received from

the connected

serial device

since the IP connection was

established.

o DTR/RTS: The

DTR/RTS Port Status

indicator displays the

current logic state of the DTR and RTS hardware handshake
(output) lines for the selected

Serial Server

port (1 = asserted, 0

= not asserted)

o DCD/DSR/CTS: The

DCD/DSR/CTS Port Status

indicator

displays the current logic state being received on the DCD,
DSR and CTS hardware handshake (input) lines of the selected

Serial Server

port (1 = asserted, 0 = not asserted)

o Status: Indicates whether the client software has made a

connection with the

Serial Server.

o IP Address: Displays the IP address of the connected client

when there is a client connection

Save Configuration File

- Allows the user to save the current

configuration information to a file with a .vcom extension.

Load Configuration File

- Allows the user to load a configuration file.