Timer 2 mode register 2 (t2m2), Atar862-4 – Rainbow Electronics ATAR862-4 User Manual
Page 52

52
ATAR862-4
4552B–4BMCU–02/03
Figure 49.
DCG Output Signals
Timer 2 Mode Register 2
(T2M2)
Address: "7"hex - Subaddress: "2"hex
If one of these output modes is used the T2O alternate function of Port 4 must also be
activated.
DCGIN
DCGO0
DCGO1
DCGO2
DCGO3
Bit 3
Bit 2
Bit 1
Bit 0
T2TOP
T2OS2
T2OS1
T2OS0
Reset value: 1111b
T2TOP
T
imer
2
T
oggle
O
utput
P
reset
This bit allows the programmer to preset the Timer 2 output T2O.
T2TOP = 0, resets the toggle outputs with the write cycle (M2 = 0)
T2TOP = 1, sets toggle outputs with the write cycle (M2 = 1)
Note: If T2R = 1, no output preset is possible
T2OS2
T
imer
2
O
utput
S
elect bit
2
T2OS1
T
imer
2
O
utput
S
elect bit
1
T2OS0
T
imer
2
O
utput
S
elect bit
0
Output
Mode
T2OS2
T2OS1
T2OS0
Clock Output (POUT)
1
1
1
1
Toggle mode: a Timer 2 compare match toggles
the output flip-flop (M2) -> T2O
2
1
1
0
Duty cycle burst generator 1: the DCG output
signal (DCG0) is given to the output and gated by
the output flip-flop (M2)
3
1
0
1
Duty cycle burst generator 2: the DCG output
signal (DCGO) is given to the output and gated by
the SSI internal data output (SO)
4
1
0
0
Biphase modulator: Timer 2 modulates the SSI
internal data output (SO) to Biphase code
5
0
1
1
Manchester modulator: Timer 2 modulates the SSI
internal data output (SO) to Manchester code
6
0
1
0
SSI output: T2O is used directly as SSI internal
data output (SO)
7
0
0
1
PWM mode: an 8/12-bit PWM mode
8
0
0
0
Not allowed