Ac characteristics for read operation – Rainbow Electronics AT27C2048 User Manual
Page 4

AT27C2048
4
Notes:
1. V
CC
must be applied simultaneously or before V
PP
, and removed simultaneously or after V
PP
.
2. V
PP
may be connected directly to V
CC
, except during programming. The supply current would then be the sum of I
CC
and I
PP
.
Note:
2, 3, 4, 5. See the AC Waveforms for Read Operation diagram.
DC and Operating Characteristics for Read Operation
Symbol
Parameter
Condition
Min
Max
Units
I
LI
Input Load Current
V
IN
= 0V to V
CC
±
1
µ
A
I
LO
Output Leakage Current
V
OUT
= 0V to V
CC
±
5
µ
A
I
PP1
(2)
V
PP
(1)
Read/Standby Current
V
PP
= V
CC
10
µ
A
I
SB
V
CC
(1)
Standby Current
I
SB1
(CMOS)
CE = V
CC
± 0.3V
100
µ
A
I
SB2
(TTL)
CE = 2.0 to V
CC
+ 0.5V
1
mA
I
CC
V
CC
Active Current
f = 5 MHz, I
OUT
= 0 mA, CE = V
IL
35
mA
V
IL
Input Low Voltage
-0.6
0.8
V
V
IH
Input High Voltage
2.0
V
CC
+ 0.5
V
V
OL
Output Low Voltage
I
OL
= 2.1 mA
0.4
V
V
OH
Output High Voltage
I
OH
= -400
µ
A
2.4
V
AC Characteristics for Read Operation
Symbol
Parameter
Condition
AT27C2048
Units
-55
-70
-90
-12
-15
Min
Max
Min
Max
Min
Max
Min
Max
Min
Max
t
ACC
(3)
Address to
Output Delay
CE = OE
= V
IL
55
70
90
120
150
ns
t
CE
(2)
CE to Output Delay
OE = V
IL
55
70
90
120
150
ns
t
OE
(2)(3)
OE to Output Delay
CE = V
IL
20
30
35
40
50
ns
t
DF
(4)(5)
OE or CE High to Output Float,
whichever occurred first
20
20
20
30
35
ns
t
OH
(4)
Output Hold from Address, CE or OE,
whichever occurred first
7
7
0
0
0
ns