beautypg.com

Rainbow Electronics DS1245Y_AB User Manual

Page 5

background image

DS1245Y/AB

041497 5/12

(V

CC

=5V

±

5% for DS1245AB)

AC ELECTRICAL CHARACTERISTICS

(t

A

: See Note 10) (V

CC

=5V

±

10% for DS1245Y)

PARAMETER

SYMBOL

DS1245Y-100

DS1245AB-100

DS1245Y-120

DS1245AB-120

UNITS

NOTES

PARAMETER

SYMBOL

MIN

MAX

MIN

MAX

UNITS

NOTES

Read Cycle Time

t

RC

100

120

ns

Access Time

t

ACC

100

120

ns

OE to Output Valid

t

OE

50

60

ns

CE to Output Valid

t

CO

100

120

ns

OE or CE to Output Active

t

COE

5

5

ns

5

Output High Z from Deselection

t

OD

35

35

ns

5

Output Hold from Address Change

t

OH

5

5

ns

Write Cycle Time

t

WC

100

120

ns

Write Pulse Width

t

WP

75

90

ns

3

Address Setup time

t

AW

0

0

ns

Write Recovery Time

t

WR1

t

WR2

5

15

5

15

ns
ns

12
13

Output High Z from WE

t

ODW

35

35

ns

5

Output Active from WE

t

OEW

5

5

ns

5

Data Setup Time

t

DS

40

50

ns

4

Data Hold Time

t

DH1

t

DH2

0

10

0

10

ns
ns

12
13