Software data protection enable algorithm, Software data protection disable algorithm, Software protected program cycle waveform – Rainbow Electronics AT28C040 User Manual
Page 8
AT28C040
8
Software Data
Protection Enable Algorithm
(1)
Notes:
1.
Data Format: I/O7 - I/O0 (Hex);
Address Format: A14 - A0 (Hex).
2.
Write Protect state will be activated at end of write
even if no other data is loaded.
3.
Write Protect state will be deactivated at end of write
period even if no other data is loaded.
4.
1 to 256 bytes of data are loaded.
Software Data
Protection Disable Algorithm
(1)
Software Protected Program Cycle Waveform
(1)(2)(3)
Notes:
1.
A0 - A14 must conform to the addressing sequence for the first 3 bytes as shown above.
2.
After the command sequence has been issued and a page write operation follows, the page address inputs (A8 - A18) must
be the same for each high to low transition of WE (or CE).
3.
OE must be high only when WE and CE are both low.
LOAD DATA AA
TO
ADDRESS 5555
LOAD DATA 55
TO
ADDRESS 2AAA
LOAD DATA A0
TO
ADDRESS 5555
LOAD DATA XX
TO
ANY ADDRESS
(4)
LOAD LAST BYTE
TO
LAST ADDRESS
ENTER DATA
PROTECT STATE
WRITES ENABLED
(2)
LOAD DATA AA
TO
ADDRESS 5555
LOAD DATA 55
TO
ADDRESS 2AAA
LOAD DATA 80
TO
ADDRESS 5555
LOAD DATA AA
TO
ADDRESS 5555
LOAD DATA 20
TO
ADDRESS 5555
LOAD DATA XX
TO
ANY ADDRESS
(4)
LOAD LAST BYTE
TO
LAST ADDRESS
LOAD DATA 55
TO
ADDRESS 2AAA
EXIT DATA
PROTECT STATE
(3)