Dc and ac operating range, Operating modes, Dc characteristics – Rainbow Electronics AT28C040 User Manual
Page 4
AT28C040
4
Notes:
1. X can be V
IL
or V
IH
.
2. Refer to AC Programming Waveforms.
DC and AC Operating Range
AT28C040-20
AT28C040-25
Operation
Operation
Read
Program
Read
Program
Operating
Temperature
(Case)
Commercial
0°C - 70°C
0°C - 70°C
0°C - 70°C
0°C - 70°C
Industrial
-40°C - 85°C
-40°C - 85°C
-40°C - 85°C
-40°C - 85°C
Extended
-55°C - 125°C
-40°C - 85°C
-55°C - 125°C
-40°C - 85°C
V
CC
Power Supply
5V
±
10%
5V
±
10%
5V
±
10%
5V
±
10%
Operating Modes
Mode
CE
OE
WE
I/O
Read
V
IL
V
IL
V
IH
D
OUT
Write
(2)
V
IL
V
IH
V
IL
D
IN
Standby/Write Inhibit
V
IH
X
(1)
X
High Z
Write Inhibit
X
X
V
IH
Write Inhibit
X
V
IL
X
Output Disable
X
V
IH
X
High Z
DC Characteristics
Symbol
Parameter
Condition
Min
Max
Units
I
LI
Input Load Current
V
IN
= 0V to V
CC
+ 1V
10
µ
A
I
LO
Output Leakage Current
V
I/O
= 0V to V
CC
10
µ
A
I
SB1
V
CC
Standby Current CMOS
CE = V
CC
- 0.3V to V
CC
+ 1V
3
mA
I
SB2
V
CC
Standby Current TTL
CE = 2.0V to V
CC
+ 1V
3
mA
I
CC
V
CC
Active Current
f = 5 MHz; I
OUT
= 0 mA
80
mA
V
IL
Input Low Voltage
0.8
V
V
IH
Input High Voltage
2.0
V
V
OL
Output Low Voltage
I
OL
= 2.1 mA
0.45
V
V
OH1
Output High Voltage
I
OH
= -400
µ
A
2.4
V
V
OH2
Output High Voltage CMOS
I
OH
= -100
µ
A; V
CC
= 4.5V
4.2
V